Inverted Thoracic Stent Graft Technique for Separation of a Stent Graft and Bare Stent Caused by Aortic Elongation

Author:

Matsumoto Ryumon1,Nishi Satoshi23ORCID,Yoshimoto Akihiro2,Suematsu Yoshihiro2

Affiliation:

1. Department of Cardiovascular Surgery, Tokyo Medical University, Tokyo, Japan

2. Department of Cardiovascular Surgery, Tsukuba Memorial Hospital, Ibaraki, Japan

3. Tsukuba Endovascular Aortic Repair Center, Tsukuba Memorial Hospital, Ibaraki, Japan

Abstract

Introduction Component separation (CS) of the Zenith Dissection Endovascular Graft and Stent have been reported with some causes. However, CS caused by aortic elongation has not yet been reported. A long treatment range with the sacrifice of some intercostal arteries (ICAs) is sometimes needed when repairing CS because of the large difference in the diameter between the proximal and distal landing zones with a reverse taper. Case presentation A 78-year-old man, who underwent thoracic endovascular aortic repair (TEVAR) using a Zenith Dissection Graft and stents for acute type B aortic dissection 3 years and 8 months previously was admitted to our hospital with severe back pain. Contrast-enhanced computed tomography (CT) showed separation of the SG and bare stent, and aortic elongation. As there was a large difference in the diameter of the proximal and distal landing zones with a reverse taper, a long treatment range with the sacrifice of two large ICAs was needed. Thus, TEVAR using an inverted thoracic SG technique was performed in order to shorten the treatment range to preserve a large ICA and reduce the risk of paraplegia. Completion angiography showed that the separation was repaired with preservation of the large ICA. The postoperative course was uneventful, and he was discharged on postoperative day 10 with relief of his severe pain. At 1 year after secondary TEVAR, CT showed that the diameter of the descending aorta had decreased with no separation of the SGs. Conclusion Deployment of an inverted thoracic SG for the treatment of CS of the Zenith Dissection Endovascular Graft and Stent is a feasible and effective procedure to preserve ICAs. An overlapping range of >1.5 times the length of a bare stent within an SG is needed to prevent CS of the Zenith Dissection Endovascular Graft and Stent caused by aortic elongation.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3