Abstract

Mesh implants as standard treatment for tissue defects can be adapted to patient’s needs by specific bioactive coatings. The biophysical interaction with the surrounding tissue must be understood to describe the influence of coatings qualitatively and quantitatively. This study investigates the use of meshes to repair diaphragmatic defects. The physical stress in this tissue is high in comparison to other applications. Therefore, knowledge gained from this experimental model can be applied to other locations. Meshes were implanted on surgically created diaphragmatic defects in growing rabbits. A standardized load model was used to investigate 33 rabbits. The commercial products Ultrapro®, Surgisis®, and Proceed ® were implanted. The adhesive properties of the meshes as well as the defect size were determined macroscopically at explantation after 4 months. Sections of the explanted meshes and diaphragms were examined histologically and immunohistochemically. The median defect size for all mesh groups decreased from the initial size of 10 mm down to 4.5 mm at explantation. No statistically significant differences were seen between the three mesh groups. Surgisis ® was found to be completely disintegrated after 4 months. Ultrapro ® and Proceed® showed no macroscopic differences compared to their original appearance. Both sealed the original diaphragmatic defect as tightly as at time of implantation. Histological and immunohistochemical analyses showed significant differences between the three mesh groups. Proceed ® caused stronger inflammatory reaction in the surrounding tissue and inferior connective tissue formation. Regarding the composition of the newly generated tissue within the defect area, Ultrapro® and Surgisis® were found superior. This can sufficiently be explained by the different gradient of inflammatory reaction in the surrounding tissue. Because Surgisis® offers no sufficiently lasting support for the diaphragmatic defect, our future main focus for mesh modification is laid on Ultrapro®.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3