E-beam sterilizable thermoplastics elastomers for healthcare devices: Mechanical, morphology, and in vivo studies

Author:

Balaji Ananad Bellam1,Ratnam Chantara Thevy2,Khalid Mohammad3ORCID,Walvekar Rashmi4

Affiliation:

1. Faculty of Engineering, Department of Chemical and Environmental Engineering, University of Nottingham Malaysia Campus, Semenyih, Selangor, Malaysia

2. Radiation Processing Technology Division, Malaysian Nuclear Agency, Bangi, Selangor, Malaysia

3. School of Science & Technology, Research Centre for Nano-materials & Energy Technology, Sunway University, Subang Jaya, Selangor, Malaysia

4. Energy Research Division, Taylor's University, Lakeside Campus, Subang Jaya, Selangor, Malaysia

Abstract

The effect of electron beam radiation on ethylene–propylene diene terpolymer/polypropylene blends is studied as an attempt to develop radiation sterilizable polypropylene/ethylene–propylene diene terpolymer blends suitable for medical devices. The polypropylene/ethylene–propylene diene terpolymer blends with mixing ratios of 80/20, 50/50, 20/80 were prepared in an internal mixer at 165°C and a rotor speed of 50 rpm/min followed by compression molding. The blends and the individual components were radiated using 3.0 MeV electron beam accelerator at doses ranging from 0 to 100 kGy in air and room temperature. All the samples were tested for tensile strength, elongation at break, hardness, impact strength, and morphological properties. After exposing to 25 and 100 kGy radiation doses, 50% PP blend was selected for in vivo studies. Results revealed that radiation-induced crosslinking is dominating in EPDM dominant blends, while radiation-induced degradation is prevailing in PP dominant blends. The 20% PP blend was found to be most compatible for 20–60 kGy radiation sterilization. The retention in impact strength with enhanced tensile strength of 20% PP blend at 20–60 kGy believed to be associated with increased compatibility between PP and EPDM along with the radiation-induced crosslinking. The scanning electron micrographs of the fracture surfaces of the PP/EPDM blends showed evidences consistent with the above contentation. The in vivo studies provide an instinct that the radiated blends are safe to be used for healthcare devices.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3