Abstract

This paper builds on an earlier examination of the influence of sampling size and analyte surface density on the accuracy and precision of measurements using surface-enhanced Raman scattering (SERS) to read out heterogeneous immunoassays. Quantitation using SERS typically relies on interrogating a small area on the sample surface by using a micrometer-sized laser spot for signal generation. The information obtained using such a small portion of sample is then projected as being representative of the much larger sample, which can compromise the accuracy and precision of the measurement due to undersampling. For a heterogeneous immunoassay interrogated by SERS, quantitation is, therefore, sensitive to the size of the analyzed area and the surface density of the measured analyte. To identify conditions in which sampling error poses a threat to accuracy and precision, a simulation of a SERS immunoassay was developed and compared to experimental results. The simulation randomly distributes adsorbates across the capture surface and then measures the density of adsorbates inside areas of analysis of different sizes. This approach mimics the analysis of a heterogeneous immunoassay when using a Raman microscope with different laser spot sizes. The results of the simulations, which were confirmed experimentally by comparison to an immunoassay of human immunoglobulin G (IgG) show that the accuracy and precision of the measurement improved with larger analysis areas and higher analyte concentrations due to the increased apparent homogeneity of the analyte within the area of analysis. By imposing a threshold on precision (5%), we also begin to establish a framework for the parameters necessary to achieve reliable quantitative measurements (e.g., laser spot size, analyte concentration, and sample volume).

Funder

National Institutes of Health

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3