Microwave-Induced Plasma Optical Emission Spectrometry (MIP OES) and Standard Dilution Analysis to Determine Trace Elements in Pharmaceutical Samples

Author:

Althoff Amanda G.1,Williams Charles B.1,McSweeney Tina2,Gonçalves Daniel A.3,Donati George L.1

Affiliation:

1. Department of Chemistry, Wake Forest University, Salem Hall, Winston-Salem, NC, USA

2. Agilent Technologies, Cary, NC, USA

3. Institute of Chemistry, Federal University of Mato Grosso do Sul, MS, Brazil

Abstract

In this work, we evaluate the application of microwave-induced plasma optical emission spectrometry (MIP OES) to determine of Al, Cr, Co, Cu, Fe, Mn, Ni and Zn in children’s cough syrup, eye drops, and oral antiseptic using standard dilution analysis (SDA). The SDA method is simple, with only two calibration solutions prepared per sample. The first solution (S1), composed of 50% sample +50% of a standard solution, is introduced into the plasma and the analytical signals are monitored in a time-resolved fashion. Then, the second solution (S2), composed of 50% sample +50% blank, is poured into the vial containing S1. As the solutions mix, the analytical signals gradually drop to a stable baseline. The calibration curve is computed by plotting the ratio of the analyte signal (SA) over the internal standard signal (which is also part of S1) (SIS) on the y-axis, versus the inverse of the IS concentration on the x-axis (i.e., SA/SIS versus 1/CIS). In this study, SDA results were compared with values obtained with the traditional methods of external calibration (EC), internal standardization (IS), and standard additions (SA) in MIP OES determinations. The precision (represented as percent RSD) for SDA showed values in the range of 2.50–8.00% for all samples, while conventional calibration methods showed RSDs in the range of 6.40–32.50% for EC, 8.30–21.80% for IS, and 5.20–17.40% for SA. The LODs calculated for SDA are below the maximum limits allowed by the major pharmaceutical regulatory agencies, and presents superior precision and accuracy compared to the traditional calibration methods. Considering its simplicity and efficiency, SDA is an important new tool for accurate analyses of pharmaceuticals.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Calibration by Proxy;Analytical Chemistry;2024-07-09

2. Multi-channel dilution analysis;Journal of Analytical Atomic Spectrometry;2024

3. Standard dilution analysis using an automatic sampler and a peristaltic pump stopping step for ICP-OES determinations;Microchemical Journal;2023-07

4. Microwave Plasma Systems in Optical and Mass Spectrometry;Encyclopedia of Analytical Chemistry;2023-06-30

5. Elemental impurities determination in bromhexine hydrochloride injections;Journal of Pharmaceutical and Biomedical Analysis;2023-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3