Time-Gated Single-Shot Picosecond Laser-Induced Breakdown Spectroscopy (ps-LIBS) for Equivalence-Ratio Measurements

Author:

Gragston Mark12ORCID,Hsu Paul3ORCID,Patnaik Anil3,Zhang Zhili1,Roy Sukesh4

Affiliation:

1. Department of Mechanical, Aerospace, and Biomedical Engineering University of Tennessee, Knoxville, TN, USA

2. Department of Mechanical, Aerospace, and Biomedical Engineering University of Tennessee Space Institute, Tullahoma, TN, USA

3. Department of Engineering Physics, Air Force Institute of Technology, Wright-Patterson AFB, OH, USA

4. Spectral Energies LLC, Beavercreek, OH, USA

Abstract

Time-gated picosecond laser-induced breakdown spectroscopy (ps-LIBS) for the determination of local equivalence ratios in atmospheric-pressure adiabatic methane–air flames is demonstrated. Traditional LIBS for equivalence-ratio measurements employ nanosecond (ns)-laser pulses, which generate excessive amounts of continuum, reducing measurement accuracy and precision. Shorter pulse durations reduce the continuum emission by limiting avalanche ionization. Furthermore, by contrast the use of femtosecond lasers, plasma emission using picosecond-laser excitation has a high signal-to-noise ratio (S/N), allowing single-shot measurements suitable for equivalence-ratio determination in turbulent reacting flows. We carried out an analysis of the dependence of the plasma emission ratio Hα (656 nm)/NII (568 nm) on laser energy and time-delay for optimization of S/N and minimization of measurement uncertainties in the equivalence ratios. Our finding shows that higher laser energy and shorter time delay reduces measurement uncertainty while maintaining high S/N. In addition to atmospheric-pressure flame studies, we also examine the stability of the ps-LIBS signal in a high-pressure nitrogen cell. The results indicate that the plasma emission and spatial position could be stable, shot-to-shot, at elevated pressure (up to 40 bar) using a lower excitation energy. Our work shows the potential of using ps-duration pulses to improve LIBS-based equivalence-ratio measurements, both in atmospheric and high-pressure combustion environments.

Funder

Air Force Research Laboratory

Air Force Office of Scientific Research

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3