Quantification of Lipid Phase Order of In Vivo Human Skin Using Attenuated Total Reflection Fourier Transform Infrared (ATR FT-IR) Spectroscopy and Multivariate Curve Resolution Analysis

Author:

Yarovoy Yury1,Drutis Dane M.1ORCID,Hancewicz Thomas M.2,Garczarek Ursula3,Ananthapadmanabhan K.P.4,Misra Manoj1

Affiliation:

1. Unilever Research & Development, Trumbull, CT, USA

2. 4102 Bridge Street, Whitehall, PA, USA

3. Cytel, Inc., Hagen, Germany

4. College of Pharmacy, University of Cincinnati, Cincinnati, OH, USA

Abstract

A new analysis methodology utilizing multivariate curve resolution (MCR) has been successfully combined with Fourier transform infrared (FT-IR) measurement of in vivo human skin to resolve lipid phase constituents in the spectra relative to high and low chain ordering. A clinical study was performed to measure lipid order through different depths of stratum corneum of human subjects. Fourier transform IR spectra were collected through the top 10 layers of the skin on four sites on the left and right forearm of 12 individuals. Depth profiling was achieved by tape stripping to remove layers of skin with 10 successive tapes from each site. In vivo ATR FT-IR spectra were collected after removing each tape. Three isolated spectral regions were analyzed, centered around 2850 cm−1, 1460–1480 cm−1, and 730 cm−1, corresponding to stretching, scissoring, and rocking –CH2 vibrational modes, respectively. Both traditional lipid conformation analysis and MCR analysis were performed on the same spectral data. The lipid order ratio, expressed as the fraction of highly ordered orthorhombic (OR) lipids to the total lipids content (orthorhombic + hexagonal [HEX] + liquid crystal [LC]), was assessed as function of depth. Lipid order depth profiles (LODP) show an increase in order with the stratum corneum depth which can be adequately described by an exponential function for the data obtained in this study. The LODP derived from the three vibrational modes show very similar trends, although the absolute order ratios are somewhat different. The variance of the skin LODP across individuals is much greater than between sites within the same individual. The higher arm sites closer to the elbow on the left and right arm show no statistically significant difference and are recommended for use in comparative studies. The scissoring mode shows the highest sensitivity for determination of LODP value.

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3