Comparison of Surface-Enhanced Raman Scattering Properties of Serum and Urine for the Detection of Chronic Kidney Disease in Patients

Author:

Zong Ming12,Zhou Lan23,Guan Qiunong2,Lin Duo4,Zhao Jianhua4,Qi Hualin5,Harriman David2,Fan Lieying1,Zeng Haishan4,Du Caigan2ORCID

Affiliation:

1. Department of Clinical Laboratory, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China

2. Department of Urologic Sciences, University of British Columbia, Vancouver, Canada

3. Department of Urology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China

4. Imaging Unit, Integrative Oncology Department, BC Cancer Research Center, Vancouver, Canada

5. Department of Nephrology, Shanghai Pudong New Area People’s Hospital, Shanghai, China

Abstract

Chronic kidney disease (CKD) affects more than 10% of the global population and is associated with significant morbidity and mortality. In most cases, this disease is developed silently, and it can progress to the end-stage renal failure. Therefore, early detection becomes critical for initiating effective interventions. Routine diagnosis of CKD requires both blood test and urinalyses in a clinical laboratory, which are time-consuming and have low sensitivity and specificity. Surface-enhanced Raman scattering (SERS) is an emerging method for rapidly assessing kidney function or injury. This study was designed to compare the differences between the SERS properties of the serum and urine for easy and simple detection of CKD. Enrolled for this study were 126 CKD patients (Stages 2–5) and 97 healthy individuals. SERS spectra of both the serum and urine samples were acquired using a Raman spectrometer (785 nm excitation). The correlation of chemical parameters of kidney function with the spectra was examined using prinicpal component analysis (PCA) combined with linear discriminant analysis (LDA) and partial least squares (PLS) analysis. Here, we showed that CKD was discriminated from non-CKD controls using PCA–LDA with a sensitivity of 74.6% and a specificity of 93.8% for the serum spectra, and 78.0% and 86.0 % for the urine spectra. The integration area under the receiver operating characteristic curve was 0.937 ± 0.015 ( p < 0.0001) for the serum and 0.886 ± 0.025 ( p < 0.0001) for the urine. The different stages of CKD were separated with the accuracy of 78.0% and 75.4% by the serum and urine spectra, respectively. PLS prediction (R2) of the serum spectra was 0.8540 for the serum urea ( p < 0.001), 0.8536 for the serum creatinine ( p < 0.001), 0.7500 for the estimated glomerular filtration rate (eGFR) ( p < 0.001), whereas the prediction (R2) of urine spectra was 0.7335 for the urine urea ( p < 0.001), 0.7901 for the urine creatinine ( p < 0.001), 0.4644 for the eGFR ( p < 0.001) and 0.6579 for the urine microalbumin ( p < 0.001). In conclusion, the accuracy of associations between SERS findings of the serum and urine samples with clinical conclusions of CKD diagnosis in this limited number of patients is similar, suggesting that SERS may be used as a rapid and easy-to-use method for early screening of CKD, which however needs further evaluation in a large cohort study.

Funder

Institute of Nutrition, Metabolism and Diabetes

Michael Smith Foundation for Health Research

Publisher

SAGE Publications

Subject

Spectroscopy,Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3