Affiliation:
1. Institute for Biodiagnostics, National Research Council of Canada, 435 Ellice Avenue, Winnipeg, Manitoba, R3B 1Y6, Canada
2. Department of Clinical Chemistry, Health Sciences Centre, Winnipeg, Manitoba, Canada
Abstract
This study assesses the potential for using mid-infrared (mid-IR) spectroscopy of dried serum films as the basis for the simultaneous quantitation of eight serum analytes: Total protein, albumin, triglycerides, cholesterol, glucose, urea, creatinine and uric acid. Infrared transmission spectra were acquired for 300 serum samples, each analysed independently using accepted reference clinical chemical methods. Quantitation methods were based upon the infrared spectra and reference analyses for 200 specimens, and the models validated using the remaining 100 samples. Standard errors in the IR-predicted analyte levels (Sy/x) were 2.8 g/L (total protein), 2.2 g/L (albumin), 0.23 mmol/L (triglycerides), 0.28 mmol/L (cholesterol), 0.41 mmol/L (glucose) and 1.1 mmol/L for urea, with correlation coefficients (IR vs reference analyses) of 0.95 or better. The IR method emerged to be less suited for creatinine (S y/ x = μmol/L) and uric acid (S y/x = 140 μmol/L) due to the relatively low concentrations typical of these analytes.
Subject
Clinical Biochemistry,General Medicine
Cited by
132 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献