A Study of Factors Influencing Continuous Flow Kinetics: The Use of Serum Calcium Estimation as a Model

Author:

Spencer Kevin1

Affiliation:

1. Department of Clinical Chemistry, East Birmingham Hospital, Bordesley Green East, Birmingham B9 5ST

Abstract

Previous studies of continuous flow kinetics have described an “AutoAnalyzer” peak in terms of two time constants, lag constant “a” and exponential constant “b”. Further investigations described here define some of the factors which affect these constants and hence peak shape and analytical performance. This communication outlines the application of this information to the development of an automated method for the determination of serum calcium, having a carry-over of less than 1 % and an analytical rate greater than 100/hour. The instaneous colour reaction, simple hydraulics, removal of the dialysis step, and the use of an integral debubbling flow cell have enabled small kinetic constants to be achieved. Over a period of three months' routine use between-batch coefficient of variation (C.V.) was 1.4%.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Reference28 articles.

1. Automated Serum Calcium Analyses Corrected for Dialysis Effects

2. A Revised Scheme for the Evaluation of Automatic Instruments for Use in Clinical Chemistry

3. “Curve regeneration” in practice in continuous flow analysis

4. Application of Analytical Methods to Automatic Analysers

5. Diebler H., Pelavin M. SMAC: The instrumentation of a high speed continuous flow analyser. Technicon International Congress, Advances in Automated Analysis. New York (1972) 7

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Automation in the Clinical Chemistry Laboratory. II. Classification and Examples;Automated Stream Analysis for Process Control;1982

2. Whither Automation?;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;1981-07

3. Comparison of Three Automated Methods of Serum Triglyceride Analysis;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;1978-01

4. An Improved Automated Method for the Analysis of Inorganic Phosphate without Dialysis;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;1978-01

5. A method for visual assessment of the performance of components in a continuous flow system;Clinica Chimica Acta;1977-06

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3