Lithium heparin interference in the Abbott enzymatic creatinine assay: the significance of under-filled tubes

Author:

Squires Maria1ORCID,Wise Helen1,Holmes Heather2,Hadfield Katie3

Affiliation:

1. Department of Clinical Biochemistry, Edinburgh Royal Infirmary, NHS Lothian, Edinburgh, UK

2. Department of Clinical Biochemistry, Victoria Hospital, NHS Fife, Kirkcaldy, UK

3. Department of Clinical Biochemistry, Airedale Hospital, Airedale NHS Foundation Trust, Keighley, UK

Abstract

Background Spuriously high results using the Abbott Architect enzymatic creatinine assay were noted to be particularly associated with very small sample volumes. This led us to query the effect of under-filling lithium heparin tubes on the measured enzymatic creatinine result. Methods Blood was provided by 5 laboratory personnel and then decanted into 5 x1.2 mL Sarstedt S-Monovette tubes, giving final blood volumes of 200, 400, 600, 800 and 1200  μL. Plasma was analysed using Abbott Architect Jaffe, enzymatic creatinine, Beckman Coulter (AU500) enzymatic creatinine and Roche (Cobas c702) enzymatic creatinine assays. Saline was also added to Sarstedt 1.2 mL and Teklab 2 mL tubes and analysed using the Abbott Jaffe and enzymatic creatinine methods. Results Increasing degrees of under-fill were associated with greater over-estimation of creatinine using the Abbott enzymatic assay, but no difference was noted using Jaffe methodology on the same platform or enzymatic assays provided by Roche or Beckman. On average, creatinine was 40.6% (+27.7  μmol/L) higher when only 200  μL of blood was present in the tube. Small volumes of saline added to lithium heparin tubes measured significant creatinine concentrations using the Abbott enzymatic method. Conclusions Lithium heparin directly interferes in the Abbott Architect enzymatic creatinine assay. Under-filling lithium heparin tubes can lead to clinically significant over-estimation of creatinine results by this assay. Users of this assay should be aware of the potential for spurious results in small sample volumes collected into lithium heparin tubes and implement robust procedures for identifying and reporting results on these samples.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Understanding the limitations of your assay using EQA data with serum creatinine as an example;Clinical Chemistry and Laboratory Medicine (CCLM);2024-04-04

2. Rapid serum tubes reduce transport hemolysis and false positive rates for high-sensitivity troponin T;Clinica Chimica Acta;2023-11

3. Variation of eGFR reporting and CKD equations used in the United Kingdom;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2023-07-07

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3