Improved technical success and radiation safety of adrenal vein sampling using rapid, semi-quantitative point-of-care cortisol measurement

Author:

Page Michael M1,Taranto Mario1,Ramsay Duncan2,van Schie Greg2,Glendenning Paul13,Gillett Melissa J1,Vasikaran Samuel D1

Affiliation:

1. Department of Clinical Biochemistry, PathWest Fiona Stanley Hospital Network, Murdoch, Western Australia, Australia

2. Department of Radiology, Royal Perth Hospital, Perth, Western Australia, Australia

3. School of Medicine, Faculty of Health and Medical Sciences, The University of Western Australia, Crawley, Western Australia, Australia

Abstract

Objective Primary aldosteronism is a curable cause of hypertension which can be treated surgically or medically depending on the findings of adrenal vein sampling studies. Adrenal vein sampling studies are technically demanding with a high failure rate in many centres. The use of intraprocedural cortisol measurement could improve the success rates of adrenal vein sampling but may be impracticable due to cost and effects on procedural duration. Design Retrospective review of the results of adrenal vein sampling procedures since commencement of point-of-care cortisol measurement using a novel single-use semi-quantitative measuring device for cortisol, the adrenal vein sampling Accuracy Kit. Measurements: Success rate and complications of adrenal vein sampling procedures before and after use of the adrenal vein sampling Accuracy Kit. Routine use of the adrenal vein sampling Accuracy Kit device for intraprocedural measurement of cortisol commenced in 2016. Results Technical success rate of adrenal vein sampling increased from 63% of 99 procedures to 90% of 48 procedures ( P = 0.0007) after implementation of the adrenal vein sampling Accuracy Kit. Failure of right adrenal vein cannulation was the main reason for an unsuccessful study. Radiation dose decreased from 34.2 Gy.cm2 (interquartile range, 15.8–85.9) to 15.7 Gy.cm2 (6.9–47.3) ( P = 0.009). No complications were noted, and implementation costs were minimal. Conclusions Point-of-care cortisol measurement during adrenal vein sampling improved cannulation success rates and reduced radiation exposure. The use of the adrenal vein sampling Accuracy Kit is now standard practice at our centre.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine