Evaluation of a Quantitative Solid Phase Reagent System for Determination of Blood Analytes

Author:

Thomas Lothar1,Plischke Wolfgang2,Storz Gunther

Affiliation:

1. Central Laboratory of the Nordwestkrankenhaus, 6000 Frankfurt

2. Scientific Department Miles GmbH, 6000 Frankfurt 71, West Germany

Abstract

In the first part of the Seralyzer system evaluation the precision and accuracy was studied with a total of 1245 clinical specimens, various commercial control sera, and pooled human sera. The calculated overall precision (between-run, and within-run) and day-to-day precision (% CV) was found to be within 3·0 to 5·4 for glucose, 2·8 to 7·1 for BUN, 1·5 to 6·2 for uric acid, 5·3 to 7·5 for bilirubin, and 3·2 to 8·6 for LDH. The clinical values are in agreement with values from respective comparative methods, as indicated by the regression statistics. The analysis of Seralyzer accuracy data using quality control sera showed in some cases a between-method difference. Supporting studies simulating additional important clinical situations showed that the clinical values for BUN, glucose, and uric acid of approximately 200 specimens from the emergency ward correlated with the respective comparative method values. In this phase of the study we verified that the instrument calibration was stable for a 24-hour period and that there is no effect of module (test) change on precision of Seralyzer determinations. The intra- and inter-laboratory performance in general practitioners' laboratories could be demonstrated using quality control sera.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Effects of Heat-oxidized Soy Protein Isolate on Growth Performance and Digestive Function of Broiler Chickens at Early Age;Asian-Australasian Journal of Animal Sciences;2015-02-14

2. Automated Enzyme Assays;Methods of Biochemical Analysis;2006-10-31

3. Fundamentals of Dry Reagent Chemistries: The Role of Enzymes;Methods of Biochemical Analysis;2006-10-31

4. Seralyzer;Dry Chemistry - Analysis with Carrier-Bound Reagents;1993

5. Analytical Reviews in Clinical Biochemistry: The Estimation of Urea;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;1992-05