Creatinine Assays: Time for Action?

Author:

Lawson Nigel,Lang Tim,Broughton Arthur,Prinsloo Peter,Turner Charles1,Marenah Christine

Affiliation:

1. Department of Paediatrics Guy's Hospital St Thomas Street London SE1 9RT, UK

Abstract

Background Major differences in creatinine results between different laboratories and apparent inaccuracies when using commercial lyophilized standards were noted. In order to assess the variation and accuracy of the different methods we conducted a local audit. Methods To establish the variation between methods, plasma creatinine was measured on 47 human plasma samples by nine different laboratories using four different methods (Roche, Ortho, Olympus, modified Olympus). To establish the accuracy of the different methods, plasma creatinine was also determined on 16 of the plasma samples by tandem mass spectrometry (MS). In addition, all the laboratories measured the creatinine concentration on a commercial authenticated sample. Results All four methods gave significantly different ( P< 0·0001) plasma creatinine results when compared with each other. Generally, creatinine results produced by the Ortho method were considerably higher than those of the other methods, especially at higher creatinine concentrations (differences across methods between the lowest and highest result for the same sample ranged between 8% and 33%). All four methods generally gave higher results than those determined by tandem MS for samples with creatinine concentrations of < 250 μmol/L. Above this concentration the Olympus and Roche methods produced creatinine results that were lower then the tandem MS results, whereas results from the Ortho method were higher. Major matrix problems were found when a commercial lyophilized standard was used for creatinine estimation. Conclusion No method gave good agreement with the tandem MS results, and there were major differences in measured plasma creatinine concentrations (up to 30% difference) between the various methods. We suggest that efforts should be made to standardize plasma creatinine measurement across all laboratories to minimize these problems.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3