Affiliation:
1. Biochemistry Department, Ronkswood Branch, Royal Infirmary, Worcester, UK
Abstract
The Boehringer one-component high-performance cholesterol oxidase reagent has been modified by the inclusion of 2,4,6-tribromo-3-hydroxybenzoic acid (TBHBA) to give a fourfold increase in sensitivity to a molar absorbance of ≈ 29 000 with respect to cholesterol. The resulting reagent system is particularly suitable for the determination of plasma HDL-cholesterol for which a reagent of high sensitivity is required. A simple method of bromination avoiding the use of elemental bromine is used to prepare TBHBA. The modified reagent system has been found to have good within- and between-batch precision and has shown itself to be reliable and trouble-free.
Subject
Clinical Biochemistry,General Medicine
Cited by
69 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献