Measurement of Plasma 1,25 Dihydroxyvitamin D Using a Novel Immunoextraction Technique and Immunoassay with Iodine Labelled Vitamin D Tracer

Author:

Fraser W D,Durham B H,Berry J L1,Mawer E B1

Affiliation:

1. University Department of Medicine, Manchester Royal Infirmary, Manchester, UK

Abstract

We evaluated a novel assay for the measurement of 1,25 dihydroxyvitamin D (1,25 (OH)2D). Immunoextraction of 1,25 (OH)2D is performed using a mini column containing a solid-phase monoclonal antibody followed by radioimmunoassay (RIA) using an 125I-labelled 1,25 (OH)2D derivative tracer and Sac-cell separation. The mean recovery of 1,25(OH)2D3 was 101%, linearity was excellent, inter- and intra-assay coefficients of variation were 9, 8 and 13% and 11, 10 and 14% at low, medium and high concentrations of 1,25(OH)2D3, respectively. The cross-reactivity of vitamin D metabolites was <0·0015% for 25-hydroxyvitamin D3, 24, 25 dihydroxyvitamin D3 and dihydrotachysterol and 0·54% for lα calcidol. 1,25 dihydroxyvitamin D2 cross-reactivity was 79%. The detection limit of the assay was 5pmol/L. Comparison with a commercial radio receptor assay (RRA) and an in-house RIA gave regression equations of y = 0·94x+11·8 ( r = 0·98) and y = 0·91x-1·7 ( r = 0.95), respectively, with no major discrepancies between the methods in all patient groups studied. Plasma concentrations of 1,25 (OH)2D obtained with the assay were as follows: normal, unsupplemented subjects: mean 88, range 48–155 pmol/L, n = 68, patients with chronic renal failure: mean 11, range 3–36 pmol/L, n = 27, primary hyperparathyroidism: mean 198, range 130–299 pmol/L, n = 23, Paget's disease: mean 92, range 42–149 pmol/L, n = 24, osteomalacia: mean 43, range 27–61 pmol/L, n = 9. A minimum sample volume of 300 μL is required, the hands-on time is significantly less than other commercial assays and the measuring procedure is gamma counting rather than scintillation counting. The assay offers several advantages over previous methods and should allow more laboratories to offer measurement of 1,25 (OH)2D as part of their repertoire.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3