Background Reference change values (RCVs) were introduced more than 30 years ago and provide objective tools for assessment of the significance of differences in two consecutive results from an individual. However, in practice, more results are usually available for monitoring, and using the RCV concept on more than two results will increase the number of false-positive results. Therefore, a simple method is needed to interpret the significance of a difference when all available serial biomarker results are considered. Methods A computer simulation model using Excel was developed. Based on 10,000 simulated data from healthy individuals, a series of up to 20 results from an individual was generated using different values for the within-subject biological variation plus the analytical variation. Each new result in this series was compared to the initial measurement result. These successive serial relative differences were computed to give limits for significant unidirectional differences with a constant cumulated maximum probability of both 95% ( P < 0.05) and 99% ( P < 0.01). Results Factors used to multiply the first result from an individual were calculated to create the limits for constant cumulated significant differences. The factors were shown to become a simple function of the number of results and the total coefficient of variation. Conclusions To interpret unidirectional differences in two or more serial results of a biomarker, the limits for significances are easily calculated using the presented factors. The first result is multiplied by the appropriate factor for increase or decrease, which gives the limits for a significant difference.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3