Acceptability of plasma ammonia results when samples are not transported and processed under ideal conditions

Author:

Bowron Ann1ORCID,Osgood Victoria1

Affiliation:

1. Department of Blood Sciences, Newcastle upon Tyne Hospitals, Newcastle upon Tyne, UK

Abstract

Background It is recommended that samples for plasma ammonia analysis are kept chilled and processed promptly as in vitro metabolism causes falsely elevated results. Rejection of unsuitable samples can cause delayed diagnosis and treatment of hyperammonaemia with potentially serious clinical consequences. The Metabolic Biochemistry Network (MetBioNet) hyperammonaemia guideline recommends analysis of samples not collected under ideal conditions and reporting with appropriate comments. An audit found that some laboratories did not follow this guidance. An investigation was performed into whether storage at controlled room temperature and delayed sample processing affected interpretation of plasma ammonia results. Methods Eleven healthy volunteers provided informed consent. Blood was taken from each into 14 paediatric EDTA blood sample tubes, one placed immediately on ice, the others in a rack at room temperature. The chilled and baseline room temperature samples were centrifuged and plasma analysed by the Roche Ammonia (NH3L2) method. Samples stored at room temperature were analysed at 10-min intervals up to 2 h. Results Baseline room temperature ammonia was higher than in the chilled sample (19 ± 6.6 µmol/L [mean ± standard deviation] and 18 ± 6.6 µmol/L, respectively). Ammonia increased further by 0.09 ± 0.02 µmol/L per minute to 30 ± 8.4 µmol/L at 2 h. No result was above the reference range (50 µmol/L). No healthy subject with normal baseline ammonia would have been erroneously identified as having hyperammonaemia. Conclusions Results support MetBioNet guidance that laboratories accept blood samples for ammonia analysis which are not processed under ideal conditions.

Publisher

SAGE Publications

Reference6 articles.

1. Suggested guidelines for the diagnosis and management of urea cycle disorders: First revision

2. Recommendations for the Diagnosis and Therapeutic Management of Hyperammonaemia in Paediatric and Adult Patients

3. Measurement of ammonia in blood

4. UK National audit of the measurement of ammonia

5. Aitkenhead H. MetBioNet guidelines for the investigation of hyperammonaemia. https://metbio.net/wp-content/uploads/MetBio-Guideline-PERE918546-10-12-2018.pdf (2018, Accessed October 2023).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3