The role of the laboratory in the diagnosis of an unusual case of Waldenstrom’s macroglobulinaemia that lacked the common clinical features: A case report

Author:

Logue Philip1ORCID,Deighan W Ian2,Gidwani Sumana1,Niblock Aaron13ORCID

Affiliation:

1. Department of Clinical Biochemistry and Haematology, Northern Health and Social Care Trust, Antrim, UK

2. Department of Clinical Biochemistry, Altnagelvin Area Hospital, Derry, UK

3. School of Medicine, Ulster University, Northern Ireland, UK

Abstract

Lymphoplasmacytic lymphoma (LPL) is a neoplasm of small B lymphocytes, plasmacytoid lymphocytes and plasma cells usually involving the bone marrow (BM). A subset of LPL which is associated with IgM monoclonal gammopathy is called Waldenstrom’s macroglobulinaemia (WM), and usually requires therapeutic intervention when a patient becomes symptomatic (Bone Marrow failure characterised by cytopenia or hyperviscosity syndrome). Here, we report the case of an 80-year-old female with clinically unsuspected WM who initially presented to the Emergency Department (ED) with nausea and vomiting. The patients’ gastrointestinal symptoms subsequently settled and was awaiting discharge. Non-specific, borderline size significant lymph nodes on CT chest was the only substantial past medical history. The diagnosis of WM was made after the Biochemistry Biomedical Scientist (BMS) detected the presence of a Type I monoclonal cryoglobulin. A potential cryoprecipitate was suspected when repeated ‘clotting’ error flags occurred during routine laboratory analyses; the sample aspiration difficulties being attributed to the viscous nature of the sample. The investigation of inaccessible low volume lymphadenopathy in the elderly should include serum protein electrophoresis and immunoglobulins as this may have established an earlier diagnosis in this case. The application of good scientific principles informed the laboratory investigation and resulted in the identification of a large IgM monoclonal cryoglobulin that prompted further appropriate investigations resulting in the diagnosis of WM. This case also highlights the importance of good communication between the laboratory and clinical staff.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Sample viscosity as a source of analytical error: The role of protein structure and mass concentration;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2023-09-29

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3