Enhanced Chemiluminescent Assay for Measuring the Total Antioxidant Capacity of Serum, Saliva and Crevicular Fluid

Author:

Chapple I L C1,Mason G I1,Garner I1,Matthews J B1,Thorpe G H2,Maxwell S R J3,Whitehead T P4

Affiliation:

1. Department of Dentistry, The University of Birmingham, Edgbaston, Birmingham, UK

2. Department of Wolfson Applied Technology Laboratory, The University of Birmingham, Edgbaston, Birmingham, UK

3. Department of Medicine, The University of Birmingham, Edgbaston, Birmingham, UK

4. Department of Pathology, The University of Birmingham, Edgbaston, Birmingham, UK

Abstract

This paper reports the development of an enhanced chemiluminescent (ECL) assay for measuring the total antioxidant (AO) capacity of serum, saliva and a fluid collectable from the gum margin called gingival crevicular fluid (GCF). The theory behind the assay is explained, and the optimum conditions for the assay, and for storage of reagents and clinical samples is described. Calibration lines were linear ( R≥0·99; P<0·0001) and the within batch coefficient of variations for a water soluble vitamin E analogue (Trolox), serum and saliva samples were <5%. In saliva and GCF, a characteristic AO response not seen in serum of the same patients, was identified. Total peripheral (serum) and local (saliva) AO capacities (μmol/L Trolox) were investigated in patients with ( n = 18) and without ( n = 16) adult periodontitis. Serum AO status did not differ between groups. Salivary total AO concentrations were lower in the periodontitis (P) group [175 (53)μmol/L] than in the nonperiodontitis (NP) group [254 (110)μmol/L1: P<0·01], as were saliva:serum AO ratio's [0·37 (0·11) versus 0·5 (0·18): P<0·01]. Periodontitis patients may have a reduced salivary AO concentration, which could result from, or predispose to, the damaging effects of reactive oxygen species (ROS). The potential for ROS production in the oral and periodontal environment may explain the presence of a specific antioxidant in oral fluids that is not detectable in serum. The ECL assay described provides a rapid, simple and reproducible method of measuring total antioxidant defence in small volumes of biological fluids.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3