Quantitative effects of bilirubin structural photoisomers on the measurement of direct bilirubin via the vanadate oxidation method

Author:

Arioka Makoto1,Koyano Kosuke1ORCID,Nakao Yasuhiro1,Ozaki Miyo2,Nakamura Shinji1,Kiuchi Hiroyuki2,Okada Hitoshi3ORCID,Itoh Susumu1,Murao Koji2,Kusaka Takashi1

Affiliation:

1. Department of Pediatrics, Faculty of Medicine, Kagawa University, Kagawa, Japan

2. Department of Clinical Laboratory, Faculty of Medicine, Kagawa University, Kagawa, Japan

3. Department of Medical Technology, Kagawa Prefectural University of Health Sciences, Kagawa, Japan

Abstract

Background Exposing blood serum samples to ambient white light-emitting diode (WLED) light may accelerate bilirubin photoisomer production. We previously demonstrated the quantitative effect of bilirubin configurational isomers (BCI) on direct bilirubin (DB) value using the vanadate oxidation method. However, the effects of bilirubin structural photoisomers (BSI) remain unclear. Methods In Study 1, the relationship between WLED irradiation time and BSI production was examined. Serum samples from five neonates were irradiated with WLED light for 0, 10, 30, 60 and 180 min. Bilirubin isomer concentration and BSI production rates were calculated. In Study 2, we performed quantitative investigation of BSI effect on DB values: Differences in DB, BCI and BSI values before and after irradiation were calculated as ⊿DB, ⊿BCI and ⊿BSI, respectively. Assuming the coefficient of BCI affecting DB values was ‘ a’, relational expression was ⊿DB = a*⊿BSI + 0.19*⊿BCI. Serum samples from 15 neonates were irradiated with green LED light for 10 and 30 s. The respective bilirubin isomer levels were measured, and the coefficient was derived. Results In Study 1, the median BSI production rate was 0.022 mg/dL per min in specimens with an unconjugated bilirubin concentration of 10.88 mg/dL. In Study 2, assuming that ⊿DB-0.19*⊿BCI was Y and ⊿BSI was X, the relational expression was Y = 0.34 X-0.03 ( R2 = 0.87; p < .01) and a = 0.34. Conclusions Under ambient WLED light, serum sample generated 1.3 mg/dL BSIs in 1 h. Approximately 34% (0.44 mg/dL) of BSI concentrations was measured as DB when using the vanadate oxidation method according to the above equation.

Funder

KAKENHI

Health Labor Sciences Research Grant

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3