Preparation of Urine Samples for Trace Metal Determination: A Study with Aluminium Analysis by Inductively Coupled Plasma Optical Emission Spectrometry

Author:

Burden T J1,Whitehead M W1,Thompson R P H1,Powell J J1

Affiliation:

1. Gastrointestinal Laboratory, The Rayne Institute, St Thomas' Hospital, London SE1 7EH, UK

Abstract

Urinary analysis of trace metals forms a significant role in clinical chemistry, but the optimal preparation and analysis of urine samples has not been investigated. Human urine is generally supersaturated with dissolved solids. Therefore, samples often precipitate following collection. X-ray microanalysis showed that this precipitate was predominantly rich in calcium and phosphorus but could include some trace metals from urine, potentially lowering their concentrations in solution. Hence, the precipitate must be fully redissolved for accurate analysis of trace metals in urine. Methods are emphasized for the best collection and preparation of urine samples for subsequent trace metal analysis; in this work inductively coupled plasma optical emission spectrometry (ICPOES) was used for the analysis of aluminium. For optimal accuracy, peak profiles were collected over 396.147 nm-396.157 nm. Urinary aluminium levels were investigated from 10 healthy volunteers and concentrations were obtained using either aqueous, pooled or individual urine-based standard curves. Since urine has a highly variable matrix, individual sample-based standards, which are unique to that particular sample, gave the most accurate results. However, where sample size is small or sample numbers are unfeasibly large, pooled sample-based standards give good approximations to within 15% and, with appropriate validation, other elements as internal standards could also be used for approximations. Aqueous standards should be avoided. Spike-recovery experiments confirmed these data since individual sample based standards showed optimal recovery [99.3 (4.4)%], while pooled sample-based standards were a close proxy [101.6 (9.2)%] but aqueous standards were inappropriate [137.4 (12.8)%]. Postprandial urinary aluminium levels of the 10 volunteers were [7.2 (3.7)μg/L] after analysis using individual sample-based standard curves.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3