Effect of Radial Neck Length on Joint Loading

Author:

Berkmortel Carolyn J1,Gladwell Michael S2,Ng Jennifer13,Ferreira Louis M134,Athwal George S34,Johnson James A134ORCID,King Graham JW34

Affiliation:

1. Department of Mechanical and Materials Engineering, Western University, London, Ontario, Canada

2. Surgery, Grey Bruce Health Services, Owen Sound, Ontario, Canada

3. Bioengineering Laboratory, Roth McFarlane Hand and Upper Limb Centre, Lawson Health Research Institute, St. Joseph’s Health Care, London, Ontario, Canada

4. Department of Surgery, Schulich School of Medicine and Dentistry, Western University, London, Ontario, Canada

Abstract

Introduction: Load transfer across the radiocapitellar joint of the elbow is poorly understood both in the setting of the native radial head and following radial head arthroplasty. The purpose of this in vitro study was to determine the effects of radial neck length, arm position, and lateral collateral ligament (LCL) repair on radial load.Methods: A uniaxial load cell was implanted into the radial neck of 8 cadaveric specimens that were mounted on an in vitro motion-control simulator and tested (in dependent, varus, and valgus arm orientations) with the native radial neck length and then −4 to +4 mm lengths. Testing was performed with the LCL intact and after sectioning and repair.Results: There was no significant difference between the 2 LCL states (P = .82), and LCL state was not protective of proximal radius overlengthening. Radial loads increased with increasing radial length (P < .001).Discussion and Conclusion: Overlengthening the radial neck resulted in higher compression forces, and underlengthening produced tensile forces, demonstrating that restoration of correct radial length during radial head arthroplasty is important to restore physiologic loading. In the varus position, tensile loading occurred, which may explain clinical problems with ingrowth of uncemented radial head implant stems and dissociation of bipolar implants.

Funder

Natural Sciences and Engineering Research Council of Canada

Canadian Institutes of Health Research

Publisher

SAGE Publications

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The effect of hemiarthroplasty implant modulus on contact mechanics: an experimental investigation;Journal of Shoulder and Elbow Surgery;2021-12

2. Primary Radial Head Arthroplasty;Arthroplasty of the Upper Extremity;2021

3. Design Considerations in Radial Head Arthroplasty;Arthroplasty of the Upper Extremity;2021