Validity of Novel Outcome Measures for Hand Function Performance After Stroke Using Egocentric Video

Author:

Tsai Meng-Fen123ORCID,Wang Rosalie H.2345,Zariffa José12356

Affiliation:

1. Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada

2. KITE, Toronto Rehabilitation Institute, University Health Network, Toronto, ON, Canada

3. Robotics Institute, University of Toronto, Toronto, ON, Canada

4. Department of Occupational Science and Occupational Therapy, University of Toronto, Toronto, ON, Canada

5. Rehabilitation Sciences Institute, University of Toronto, Toronto, ON, Canada

6. Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, Toronto, ON, Canada

Abstract

Background Evaluating upper limb (UL) interventions after stroke calls for outcome measures that describe impact on daily life in the community. UL use ratio has been used to quantify the performance domain of UL function, but generally focuses on arm use only. A hand use ratio could provide additional information about UL function after stroke. Additionally, a ratio based on the role of the more-affected hand in bilateral activities (stabilizer or manipulator) may also reflect hand function recovery. Egocentric video is a novel modality that can record both dynamic and static hand use and hand roles at home after stroke. Objective To validate hand use and hand role ratios from egocentric video against standardized clinical UL assessments. Methods Twenty-four stroke survivors recorded daily tasks in a home simulation laboratory and their daily routines at home using egocentric cameras. Spearman’s correlation was used to compare the ratios with the Fugl-Meyer Assessment-Upper Extremity (FMA-UE), Action Research Arm Test (ARAT), and Motor Activity Log-30 (MAL, Amount of Use (AoU), and Quality of Movement (QoM)). Results Hand use ratio significantly correlated with the FMA-UE (0.60, 95% CI: 0.26, 0.81), ARAT (0.44, CI: 0.04, 0.72), MAL-AoU (0.80, CI: 0.59, 0.91), and MAL-QoM (0.79, CI: 0.57, 0.91). Hand role ratio had no significant correlations with the assessments. Conclusion Hand use ratio automatically extracted from egocentric video, but not hand role ratio, was found to be a valid measure of hand function performance in our sample. Further investigation is necessary to interpret hand role information.

Funder

Heart and Stroke Foundation of Canada

Publisher

SAGE Publications

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Wearable Technologies for Monitoring Upper Extremity Functions During Daily Life in Neurologically Impaired Individuals;IEEE Transactions on Neural Systems and Rehabilitation Engineering;2024

2. Feasibility of a Portable, Wearable, High-Density Surface EMG Device for Detecting Functional Hand-Object Interactions;2023 IEEE International Conference on Metrology for eXtended Reality, Artificial Intelligence and Neural Engineering (MetroXRAINE);2023-10-25

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3