Test-Retest, Interrater Reliability, and Minimal Detectable Change of the Dynamic Exertion Test (EXiT) for Concussion

Author:

Sinnott Aaron M.,Eagle Shawn R.ORCID,Kochick Victoria,Bricker Indira R.,Collins Michael W.,Sparto Patrick J.,Flanagan Shawn D.,Elbin R. J.,Connaboy Christopher,Kontos Anthony P.

Abstract

Background: The Dynamic Exertion Test (EXiT) was developed to inform return-to-play (RTP) decision-making following clinical recovery from sport-related concussion (SRC). The purpose of the current study was to document intrarater and test-retest reliability and minimal detectable change (MDC) scores for physiological [heart rate (HR) and blood pressure], performance (change-of-direction task completion time and errors), and clinical outcomes (endorsed symptoms, perceived exertion) of EXiT, and interrater reliability of performance outcomes. Hypothesis: Healthy athletes would exhibit stable physiological responses to the EXiT across visits, demonstrate consistent change-of-direction task completion time between consecutive trials at each visit, and the fastest time (of 2 trials) across visits, and endorse equivocal symptoms and effort across visits. Study Design: Cross-sectional, test-retest. Level of Evidence: Level 3. Methods: Seventy-nine (female: 34 [43%], 19.6 ± 5.0 years) athletes completed the EXiT at 2 study visits (8.7 ± 4.7 days between visits). Two-way, mixed, intraclass correlation coefficients (ICCs) were used to evaluate intrarater and test-retest reliability. Cronbach’s alpha was used to document the internal consistency of symptoms at each visit, and MDC scores were calculated on the physiological, performance, and clinical outcomes. Results: Measured and percentage of age-estimated maximum HR were reliable following EXiT (ICC = 0.579-0.618). Change-of-direction task completion time (MDC range = 0.75-8.70 s) had good-to-excellent test-retest (ICC = 0.703-0.948) and interrater (ICC = 0.932-0.965) reliability. Symptoms had a high internal consistency at visits 1 ( α = 0.894) and 2 ( α = 0.805) and were reliable across visits (ICC = 0.588). Conclusion: The current investigation established test-retest reliability in addition to MDC scores of an objective dynamic exercise assessment among healthy adolescent and adult athletes. The EXiT may be an objective approach to inform RTP decision-making following SRC recovery. Clinical Relevance: The EXiT is a clinically feasible exertion-based assessment that can be readily administered in a variety of outpatient clinical settings.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3