Reliability of a New Clinical Instrument for Measuring Internal and External Glenohumeral Rotation

Author:

Lindenfeld Thomas N.1,Fleckenstein Cassie M.1,Levy Martin S.2,Grood Edward S.1,Frush Todd J.3,Parameswaran A. Dushi4

Affiliation:

1. Cincinnati Sports Medicine Research and Education Foundation, Cincinnati, Ohio

2. University of Cincinnati, Cincinnati, Ohio

3. Porretta Center for Orthopaedic Surgery-Novi Orthopaedic Center, Novi, Michigan

4. Reconstructive Orthopedic Center of Houston, Houston, Texas

Abstract

Background: The shoulder plays a critical role in many overhead athletic activities. Several studies have shown alterations in shoulder range of motion (ROM) in the dominant shoulder of overhead athletes and correlation with significantly increased risk of injury to the shoulder and elbow. The purpose of this study was to measure isolated glenohumeral joint internal/external rotation (IR/ER) to determine inter- and intraobserver reliability of a new clinical device. Hypothesis: (1) Inter- and intraobserver reliability would exceed 90% for measures of glenohumeral joint IR, ER, and total arc of motion; (2) the dominant arm would exhibit significantly increased ER, significantly decreased IR, and no difference in total arc of motion compared with the nondominant shoulder; and (3) a significant difference exists in total arc between male and female patients. Study Design: Case series. Level of Evidence: Level 4. Methods: Thirty-seven subjects (mean age, 23 years; range, 13-54 years) were tested by 2 orthopaedic surgeons. A single test consisted of 1 arc of motion from neutral to external rotation to internal rotation and back to neutral within preset torque limits. Each examiner performed 3 tests on the dominant and nondominant shoulders. Each examiner completed 2 installations. Results: Testing reliability demonstrated that neither trial, installation, nor observer were significant sources of variation. The maximum standard deviation was 1.3° for total arc of motion and less than 2° for most other measurements. Dominant arm ER was significantly greater than nondominant arm ER ( P = 0.02), and dominant arm IR was significantly less than nondominant arm IR ( P = 0.00). Mean total rotation was 162°, with no significant differences in total rotation between dominant and nondominant arms ( P = 0.34). Mean total arc of motion was 45° greater in female subjects. Differences in total arc of motion between male and female subjects was statistically significant ( P < 0.00). Conclusion: This simple, clinical device allows for both inter- and intraobserver reliability measurements of glenohumeral internal and external rotation.

Publisher

SAGE Publications

Subject

Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3