Test–retest reliability and validity of normative cut-offs of the two devices measuring touch threshold: Weinstein Enhanced Sensory Test and Pressure-Specified Sensory Device

Author:

Uddin Zakir12,MacDermid Joy C13,Ham Hyungjoo H1

Affiliation:

1. School of Rehabilitation Science, McMaster University, Hamilton, ON, Canada

2. Department of Physical Medicine, Bangladesh University of Health Sciences, Dhaka, Bangladesh

3. Clinical Research Lab, Hand and Upper Limb Centre, St. Joseph’s Health Centre, London, ON, Canada

Abstract

Introduction Touch threshold screening instruments must accurately distinguish normal versus abnormal sensation to screen nerve pathology. This study was conducted to find out whether two touch threshold measuring devices (i.e. Weinstein Enhanced Sensory Test (WEST) and Pressure-Specified Sensory Device (PSSD) provide consistent results and indicators of “normal” sensation, and secondarily what rules best define normality. Methods The study design was a cross-sectional reliability and validity assessment with 23 healthy participants. Instruments were applied in random order on the pulp of the middle and little fingers of both hands; with five applications on each digit. Cut-offs of 3, 4, and 5 correct responses were used to classify the response as being normal. Weighted kappa and percent agreement were used to indicate test–retest reliability of the WEST, and validity was determined by calculating the percentage of normal controls that achieved a normal score. The Bland–Altman method was used to characterize the retest reliability of PSSD, and validity was determined by whether the mean of the score is different from the normative scores. Results The agreement between test and retest of WEST (detection level = 3/5) was almost perfect ( k = 1). The average percentages of normal detection of the WEST on two test/retest were 93% and 97% (detection level = 4/5) and 82% and 85% (detection level = 5/5). All mean PSSD tests values were found within the predetermined normal range. The Bland–Altman plot demonstrated a minimal mean difference between test occasions and similar limits of agreement across the four test locations. Discussion The study found that more than 90% of the tests with healthy young participants were reliable and valid in relation to their ability to detect a normal WEST filament or PSSD within a normal force range. Our study was limited by a small sample with healthy participants.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3