Fibrin Sealant TISSEEL Lyo as a haemostatic agent in vascular surgery: Results of randomized, controlled, patient-blinded, multicentre clinical study in the Russian population

Author:

Karpenko Andrey A1,Cheban Alexey V1ORCID,Rabtsun Artem A1,Sokurenko German Y2,Andreychuk Konstantin A2,Kim Igor N3,Volf Valentin A3,Kuznetsov Maksim R45,Prostov Igor I6,Sapronova Natalia G6,Mzhavanadze Nina D7ORCID,Kamaev Alexey A7,Suchkov Igor A7ORCID

Affiliation:

1. National Research Center Named after Academician E.N. Meshalkin, Novosibirsk, Russia

2. A.M. Nikiforov All-Russian Center of Emergency and Radiation Medicine, St-Petersburg, Russia

3. State Novosibirsk Regional Clinical Hospital, Novosibirsk, Russia

4. Institute of Cluster Oncology Named after L. L. Levshin of the Sechenov University, Moscow, Russia

5. City Clinical Hospital Named after S. S. Yudin, Moscow, Russia

6. Rostov State Medical University, Rostov-on-Don, Russia

7. Ryazan State Medical University Named after Academician I.P. Pavlov, Ryazan, Russia

Abstract

Background: This phase III, controlled, patient-blinded, multicentre study in two parallel, equal-sized treatment groups compared the efficacy and safety of TISSEEL Lyo, fibrin sealant versus Manual Compression (MC) with surgical gauze pads for use as a haemostatic agent in patients who underwent vascular surgery in Russia. Methods: Adult patients, both genders, who received peripheral vascular expanded polytetrafluoroethylene conduits and had suture line bleeding after surgical haemostasis were enrolled. Patients were randomized to be treated with TISSEEL Lyo or MC. The bleeding needed additional treatment and had to be assessed as grade 1 or 2 bleeding according to the Validated Intraoperative Bleeding scale. The primary efficacy endpoint was the proportion of patients achieving haemostasis at 4 min after treatment application (T4) at the study suture line, which was maintained until the closure of the surgical wound. The secondary efficacy endpoints included the proportion of patients achieving haemostasis at 6 min (T6) and 10 min (T10) after treatment application at the study suture line, which was maintained until closure of the surgical wound, as well as the proportion of patients with intraoperative and postoperative rebleeding. Safety outcomes included incidence of adverse events (AEs), surgical site infections and graft occlusions. Results: A total of 110 patients were screened; 104 patients were randomized: (TISSEEL Lyo: 51 [49%] patients; MC: 53 [51%] patients). T4 haemostasis was achieved in 43 (84.3%) patients in the TISSEEL Lyo group and in 11 (20.8%) patients in the MC group ( p < 0.001). Significantly more patients in TISSEEL Lyo group achieved the haemostasis at T6 (relative risk (RR) of achieving haemostasis 1.74 [95% confidence interval (CI) 1.37; 2.35]) and T10 (RR 1.18 [95% CI 1.05; 1.38]) versus MC. No one had intraoperative rebleeding. Postoperative rebleeding was reported only in one patient in the MC group. No treatment-emergent serious AEs (TESAEs) related to TISSEEL Lyo/MC, TESAEs leading to withdrawal and TESAEs leading to death were reported in patients during the study. Conclusions: Data demonstrated TISSEEL Lyo had clinically and statistically significant superiority to MC as a haemostatic agent in vascular surgery at all measured time points including 4, 6 and 10 min and had proven to be safe.

Funder

Fibrin Sealant TISSEEL Lyo as a hemostatic agent in vascular surgery: randomized, multicenter clinical study in the Russian population.

Publisher

SAGE Publications

Subject

Multidisciplinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3