Therapy of Sustained Ventricular Arrhythmias With Amiodarone: Prediction of Efficacy With Serial Electrophysiologic Studies

Author:

Nasir Nadim1,Swarna Udaya S.1,Boahene Kwabena A.1,Doyle Timothy K.1,Pacifico Antonio1

Affiliation:

1. The Texas Arrhythmia Institute, 6560 Fannin, Suite 620. Houston. TX 77030.

Abstract

Background: Programmed electrical stimulation early during amiodarone therapy has poor prognostic capabilities; and persistent inducibility has been associated with a favorable outcome in a majority of patients. These observations result from studies that differed significantly in methodology. Methods and Results: The authors prospectively enrolled 121 patients in a standardized amiodarone dosing protocol in which amiodarone was the only antiarrhythmic agent. Electrophysiologic testing was done after 2 and 6 weeks to determine noninducibility, predictive value, and the significance of drug-induced prolongation of tachycardia cycle length. The mean age of the patients in the study was 63.2 ± 11.5 years, and their ejection fraction was 32.8 ± 11.9%. Coronary artery disease was present in 103 (85%). At 2 weeks 17 patients (14%) were no longer inducible, whereas 101 patients (86%) remained inducible. Patients in these groups were similar in age and ejection fraction. During follow-up evaluation, recurrences (35% vs 24%; P =.44) and sudden death (12% vs 13.5%) were similar in the two groups. Thirty-five of 95 patients (32%) with sustained monomorphic ventricular tachycardia had more than 100 ms prolongation of their cycle length, which was hemodynamically well tolerated (partial response), but 60 did not (nonresponse). Patients with a partial response were older (66.5 vs 61.1 years; P =.02) and had longer QRS durations (143.2 vs 129.4 ms; P =.03). They also had increased recurrences (37% vs 17%; P =.01) and more sudden deaths (23% vs 8%; P =.02). At 6 weeks 11 of 76 patients studied were noninducible. They had a lower recurrence rate than those who remained inducible (8% vs 27%; P =.02) but a similar number of sudden deaths (8% vs 16%; P =.27). Thirty-two patients partially responded, and 31 patients did not respond. During follow-up examination these two groups had a similar number of recurrences (25% vs 29%; P =.76) and sudden deaths (16% vs 16%). Conclusions: Noninducibility at 2 or 6 weeks of amiodarone therapy did not identify patients at low risk of sudden death. In inducible patients, tachycardia cycle length prolongation, even when well tolerated, was not a marker for favorable outcome. Electrophysiologically guided therapy. therefore. offers little benefit over empiric amiodarone. Conclusions: Noninducibility at 2 or 6 weeks of amiodarone therapy did not identify patients at low risk of sudden death. In inducible patients, tachycardia cycle length prolongation, even when well tolerated, was not a marker for favorable outcome. Electrophysiologically guided therapy. therefore. offers little benefit over empiric amiodarone.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Pharmacology

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ventricular Tachycardia;Management of Complex Cardiovascular Problems;2016-04-22

2. Antiarrhythmic Drugs;Electrophysiological Disorders of the Heart;2012

3. Individual Patterns of Dynamic QT/RR Relationship in Survivors of Acute Myocardial Infarction and Their Relationship to Antiarrhythmic Efficacy of Amiodarone;Journal of Cardiovascular Electrophysiology;2004-10

4. Class I or Class III Agents for Atrial Fibrillation:. Are We Asking the Right Question?;Pacing and Clinical Electrophysiology;2003-07

5. Combination IK1 and IKr channel blockade: no additive lowering of the defibrillation threshold;Canadian Journal of Physiology and Pharmacology;2002-01-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3