A Novel Amiodarone-Eluting Biological Glue for Reducing Postoperative Atrial Fibrillation

Author:

Beckerman Ziv1,Azran Adi2,Cohen Oved1,Nir Rony-Reuven1,Maessen Jos G.3,Bianco-Peled Havazelet1,Bolotin Gil1

Affiliation:

1. Department of Cardiac Surgery, Rambam Health Care Campus, Haifa, Israel

2. Chemical Engineering Department, Technion, Haifa, Israel

3. Department of Cardiothoracic Surgery, Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands

Abstract

Objective: Postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, leading to increased morbidity and mortality. The aim of this preliminary study was to evaluate a novel drug delivery system for local release of amiodarone. Methods: In the current prospective study, 9 goats underwent attachment of right atrial (RA) epicardial electrodes. Alginate-based glue with amiodarone was applied to the RA of the treatment groups. Rapid atrial response (RAR) to burst pacing was assessed before application and in the third postoperative day (POD3). Average RAR frequency was defined as the average percentage of inductions resulting in RAR per animal. Myocardial and extracardiac tissue amiodarone concentrations were analyzed. Results: Differences in RAR proportions between baseline and POD3 were greater in the treatment group versus the control group ( P = .034). Average RAR frequency was reduced by 34% in the treatment group (baseline: 65%; POD3: 31%), while it was increased by 11.3% in the control (baseline:43.8%; POD3: 55%). The treatment group demonstrated a greater proportion of animals meeting the success criterion of net percentage reduction in RAR frequency greater than 25% ( P = .047). The average amount of total amiodarone detected in the RA was 104.4 ± 28.9 µg; the transmural concentration was linearly distributed ( P < .0001). Extracardiac tissue concentrations were below the detection level. Conclusions: Local alginate-based amiodarone delivery demonstrated an RAR frequency reduction of clinical importance in response to burst pacing. The electrophysiological response was achieved while maintaining below-detection systemic drug levels. Current findings may point to the system’s future applicability in reducing POAF risk in humans.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Pharmacology

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3