Monitoring of Anti-Xa in Pregnant Patients With Mechanical Prosthetic Valves Receiving Low-Molecular-Weight Heparin

Author:

Goland Sorel1,Schwartzenberg Shmuel1,Fan John23,Kozak Natasha1,Khatri Nudrat23,Elkayam Uri23

Affiliation:

1. Heart Institute, Kaplan Medical Center, Affiliated to the Hebrew University and Hadassah Medical School, Jerusalem, Israel

2. Department of Medicine, Division of Cardiovascular Disease, University of Southern California, Los Angeles, CA, USA

3. Department of Obstetrics and Gynecology, University of Southern California, Los Angeles, CA, USA

Abstract

Objectives: We hypothesized that the guideline-recommended peak anti-Xa levels for pregnant women with mechanical prosthetic heart valves (MPHVs) receiving adjusted dose low-molecular-weight heparin (LMWH) are associated with subtherapeutic trough levels and consequently with an inadequate level of anticoagulation. Background: Low-molecular-weight heparin is often used for anticoagulation in pregnant women including those with MPHV. American College of Cardiology/American Heart Association guidelines recommend monitoring of plasma anti-Xa factor peak levels and adjustment of the dose to achieve peak levels of 0.7 to 1.2 U/mL. In spite of these recommendations, cases of valve thrombosis during pregnancy continue to occur. Methods and Results: We studied 30 pregnant patients receiving anticoagulation for various indications with adjusted dose LMWH given subcutaneously twice a day which had both trough and peak anti-Xa levels throughout pregnancy for a total of 187 paired determinations. The recommended peak anti-Xa levels (0.7-1.2 U/mL) were obtained in 123 (66%) of the measurements but in 80% of them, the trough levels were found to be subtherapeutic (<0.6 U/mL). Subtherapeutic trough levels were found in 8 (73%) of the 11 measurements with peak levels of 0.7 to 0.79 U/mL, 17 (74%) of the 23 of 0.8 to 0.89 U/mL, 21 (72%) of the 29 of 0.9 to 0.99 U/mL, and 28 (44%) of the 63 of 1.0 to 1.2 U/mL. There were 42 measurements with peak anti-Xa levels >1.2 U/mL and even in these cases, 13 (31%) of the trough levels were found to be subtherapeutic. Conclusions: Anticoagulation with adjusted dose LMWH aimed to achieve guideline-recommended peak levels of anti-Xa for patients with MPHVs is commonly associated with subtherapeutic trough levels. Routine measurement of trough anti-Xa levels is therefore advisable in women with MPHV treated with LMWH during pregnancy to assure adequate level of anticoagulation.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Pharmacology

Cited by 50 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3