Validation of Temperature Sensors to Monitor Thermoplastic Splint Wear in Hand Surgery Patients

Author:

Weir Tristan B.1ORCID,DeTullio Lauren1,Patel Saral J.1,Lorenzana Daniel J.1,Arango Sebastian D.1,Livesey Michael G.2,Gilotra Mohit N.2ORCID,Osterman A. Lee1,Miller Andrew J.1

Affiliation:

1. Thomas Jefferson University Hospital, Philadelphia, PA, USA

2. University of Maryland School of Medicine, Baltimore, USA

Abstract

Background: The aim of this study was to validate the use of temperature sensors to accurately measure thermoplastic volar forearm splint wear in a healthy cohort of volunteers using 5- and 15-minute temperature measurement intervals. Methods: A prospective diagnostic study was performed to evaluate the diagnostic accuracy of temperature sensors in monitoring splint wear in 8 healthy volunteers between December 2022 and June 2023. Temperature sensors were molded into thermoplastic volar forearm splints. Volunteers who were familiar with the study aims were asked to keep an exact log of the time spent wearing the splint (“actual wear time”). Sensors recorded temperatures every 5 or 15 minutes, and separate algorithms were developed to determine the sensor-detected wear time compared with the actual wear time as the gold standard. The algorithms were then externally validated with the total population. Results: The 5-minute and 15-minute algorithms demonstrated excellent sensitivity (99.1% vs 96.6%), specificity (99.9% vs 99.9%), positive (99.4% vs 99.5%) and negative (99.9% vs 99.3%) predictive value, and diagnostic accuracy (99.8% vs 99.3%), respectively. The 5-minute algorithm recorded 99.5% of the total splint hours, whereas the 15-minute algorithm recorded 96.1%. There was no significant difference between the actual time per wear session (5.4 ± 2.7 hours) and the time estimated by the 5-minute algorithm (5.4 ± 2.6 hours; P = .40), but there was a significant difference for the 15-minute algorithm (5.2 ± 2.6 hours; P < .001). Conclusion: Temperature sensors can be used to accurately monitor thermoplastic volar forearm splint wear. Level of Evidence: Diagnostic II.

Funder

Hand Rehabilitation Foundation

Publisher

SAGE Publications

Reference27 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3