Rheological Properties of Elastomeric Impression Materials Before and During Setting

Author:

McCabe J.F.1,Arikawa H.2

Affiliation:

1. Dental Materials Science Unit, The Dental School, University of Newcastle upon Tyne, Framlington Place, Newcastle upon Tyne, NE2 4BW, United Kingdom

2. Dental Materials Science Unit, The Dental School, University of Newcastle upon Tyne, Framlington Place, Newcastle upon Tyne, NE2 4BW, United Kingdom, Department of Dental Materials Science, Kagoshima University Dental School, 8-35-1 Sakuragaoka, Kagoshima 890, Japan

Abstract

In this study, we examined the rheological properties of elastomeric impression materials, both before and during setting, to assess the clinical significance of certain key characteristics such as viscosity, pseudo-plasticity, and the rate of development of elasticity. The hypothesis to be tested was that monitoring the change in tan 8 is the most appropriate means of monitoring the setting characteristics of elastomers. The loss tangent (tan 8) and the dynamic viscosity (η') for five impression materials (both unmixed pastes and mixed/setting materials) were measured by means of a controlled-stress rheometer in a cone/plate configuration. For unmixed pastes, tests were performed at various frequencies (0.1 to 10 Hz) and torques (from 1 to 50 x 10-4 Nm), while testing on setting materials was performed at constant frequency (1 Hz) and torque (3 x 10-3 Nm). Most base and catalyst pastes were pseudoplastic before being mixed. Immediately after being mixed, the polyether (tan 8 = 9.85) and polysulfide (tan 8 = 9.54) elastomers showed tan 8 markedly higher than those of other mixed materials (tan 8 = 4.96 to 3.01). The poly-vinylsiloxane elastomers showed lower initial tan 8, which rapidly reduced even further with time. This suggests that these materials should be used as soon as possible after being mixed. The polyether elastomer had a comparatively long induction period during which the tan 8 remained at a high value. These characteristics are thought to be key factors in controlling clinical efficacy and therefore support the hypothesis that monitoring tan 8 is an appropriate method for evaluating the setting characteristics of elastomers. One limitation was that the controlled-stress rheometer was unable to monitor rheological properties through to completion of setting.

Publisher

SAGE Publications

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3