Analysis of Possible Cross-Contamination with the Venturi System Atomizer

Author:

Scianna Joseph M.1,Chow James M.1,Hotaling Andrew1

Affiliation:

1. Department of Otolaryngology, Loyola University Medical Center, Maywood, Illinois

Abstract

Background The physics behind the Venturi atomizers suggest a possibility of bacterial colonization and the potential for patient cross-contamination. A protocol for use of the atomizer and clinically appropriate demonstration of cross contamination has not been established. Methods Three sterilized atomizers filled with a solution of 2% Pontocaine and 1% ephedrine (two test and one control) were used during a 5-day study period. Clinic staff was instructed to (1) use a nozzle tip, (2) use a nasal speculum, (3) avoid contact between the atomizer and the patient, and (4) apply a continuous, <1-second spray to the nasal cavity. Samples were obtained from each of the atomizers three times per day and plated on chocolate agar plates. The number and type of bacterial colony were registered. Results No respiratory pathogens grew from any of the 45 plated samples. Nine of 30 experimental atomizer samples produced 12 bacterial colonies. Of the 12 bacterial colonies obtained, 6 colonies of coagulase-negative Staphylococcus, 5 colonies of Corynebacterium sp., and 1 colony of Bacillus sp. were identified. One of 15 plated control atomizer samples produced two colonies of coagulase-negative Staphylococcus. An average of 1.3 colonies per positive test plate and an average of 2.0 colonies per positive control plate were identified. There was no evidence of an increasing number of colonies per plate or persistence of any particular bacteria identified over time to suggest contamination or colonization of the system reservoir. Conclusion There is no risk of cross-contamination of patients with the use of the Venturi system atomizer as outlined in this study. Culture results from this study were consistent with random culture contamination during the plating and/or culturing period. There was no evidence to support the idea of bacterial colonization of the atomizers. Continued use of the Venturi system atomizer is an acceptable practice.

Publisher

SAGE Publications

Subject

Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3