Abstract

Background. While biomechanical characteristics of locking screw fixation versus traditional plating has been studied extensively in orthopaedic literature, clinical outcome studies are lacking. The goal of this study was to evaluate the efficacy and complications rate of locking versus traditional nonlocking screws in complex ankle fractures employing distal fibula internal fixation with 1/3 semitubular small fragment plates. Methods. A retrospective review was performed between January 2010 and June 2013 of all patients in whom internal fixation of the fibula in an ankle fracture (open or closed) was performed using only 1/3 semitubular small fragment fibular plates. Patient characteristics, fracture patterns, specific screw choice that were placed in the most distal 2 fibular plate holes (either locking or nonlocking), infectious wound complications, and concomitant syndesmotic injury and the need and corresponding purpose for hardware removal were recorded. Results. A total of 135 patients were found to meet inclusion criteria and were analyzed for this study. Of the patients with locking screws, 25 of 98 (25%) elected to have hardware removed, while 13 of 37 (35%) of those with nonlocking screws elected hardware removal. This did not reach statistical significance (P = .30). There was no statistically significant difference between the groups with regards to age, smoking status, body mass index, diabetes, or use of syndesmotic screw fixation. There was no significant difference in loss of fixation, infection, or other surgical complications in between the groups. Conclusions. There was no significant decrease in the rate of hardware removal with the use of 1/3 tubular locking versus nonlocking plates in the treatment of distal fibula fractures. Despite these screws locking flush to the plate, the hardware is equally symptomatic in both groups. There was no significant difference in the rate of complications between the 2 groups and our data suggest that the added expense of using locking screws routinely when fixing lateral malleolar fractures should be carefully considered, especially if the fracture pattern does not warrant locking technology. Levels of Evidence: Prognostic, Level III

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Podiatry,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3