Abstract

Introduction Biomechanical studies have proved that locking plates have better primary stability besides versatility regarding fracture pattern while reducing bone contact and bridging the gap, whereas conventional nonlocking plates (plus lag screw) depend on bone-plate compression. The clinical benefit of locking plates over nonlocking plates remains unanswered, however. Therefore, this retrospective cohort study was set up to test the hypothesis that the use of locking plates for unstable ankle fractures will result in fewer re-displacements, superior bony healing, and functional and clinical outcomes better than observed in the nonlocking cohort. Methods Bimalleolar ankle fractures (AO 44-B2) without syndesmotic injury treated with either a locking or a nonlocking plate were included. Groups were compared for complications, bone healing, secondary dislocation, progressions of osteoarthritis, and clinical outcome using patient-reported outcome measures. Results Data revealed no clinical outcome differences (Olerud-Molander Ankle Score: nonlocking 88.2 ± 14.4, locking 88.8 ± 12.3, P = .69, robust two 1-sided test for equality (RTOST): P = .03; American Orthopaedic Foot and Ankle Score: nonlocking 91.2 ± 12.9, locking 91.8 ± 11.3, P = .96, RTOST: P = .04). Nevertheless, a significant postoperative progression of osteoarthritis was detected in both groups (P = .04). This was independent of implant (P = .16). Although difference was not significant, locking plates were preferred in older (P = .78) and sicker patients (P = .63) and in cases with severer osteoarthritis (P = .16), and were associated with a higher complication rate (P = .42) and secondary dislocation (nonlocking 9.4%, locking 18.2%; P = .42). Re-displacement, however, was not a compelling reason for revision. Conclusions The present study shows statistically significant equality of both types of implants. Contrary to our expectation, locking plates seemed to be associated with a higher risk for re-displacement. Overall, the use of either locking or nonlocking plates for unstable AO 44-B2 fractures is safe and successful despite significant progression of osteoarthritis. Level of Evidence: III, Retrospective observational cohort study

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Podiatry,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3