Evaluation of the Precision Xtra meter for monitoring blood β-hydroxybutyrate concentrations in late-gestation ewes

Author:

Ratanapob Niorn123ORCID,VanLeeuwen John123,McKenna Shawn123,Wichtel Maureen123ORCID,Rodriguez-Lecompte Juan C.123,Menzies Paula123,Wichtel Jeffrey123

Affiliation:

1. Departments of Health Management (Ratanapob, VanLeeuwen, McKenna, M Wichtel), Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada

2. Pathology and Microbiology (Rodriguez-Lecompte), Atlantic Veterinary College, University of Prince Edward Island, Charlottetown, Prince Edward Island, Canada

3. Department of Population Medicine, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada (Menzies, J Wichtel)

Abstract

Blood samples were collected from late-gestation ewes to determine the agreement of a point-of-care (POC) Precision Xtra meter and a standard laboratory test for β-hydroxybutyrate (BHBA). Fresh whole blood samples were immediately tested with the POC instrument, and serum samples were analyzed with a standard commercial biochemical analyzer. Ewes were classified as having ketonemia if their BHBA concentrations were ≥800 µmol/L. Scatter plots, paired t-tests, Bland–Altman limits of agreement, and Gwet AC1 tests were used to compare results. The 2 tests had very good agreement. The values between instruments were not statistically different based on paired t-tests ( p = 0.312). The intercept and slope of a linear mixed model, containing the standard test results as an outcome and the POC meter results as a predictor, were 0.02 (95% CI: 0.00, 0.04) and 0.98 (95% CI: 0.96, 1.01), respectively. When the samples were classified into ketonemic classes (non-ketonemic and ketonemic) based on BHBA concentrations obtained from each test, the Gwet AC1 statistic was 0.94 (95% CI: 0.91, 0.97; p < 0.001). The ketosis classification agreed in 95% of samples. Based on the Bland–Altman plot and limits of agreement, the optimal cutoff to diagnose ketonemia with the POC meter was 1,000 µmol/L, which is 200 µmol/L higher than the laboratory BHBA medical decision limit. The Precision Xtra meter provided excellent correlation and substantial agreement with the standard laboratory technique for measuring blood BHBA in late-gestation ewes.

Funder

The Province of Prince Edward Island Agriculture Research and Innovation Program

Publisher

SAGE Publications

Subject

General Veterinary

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3