The Impact of Grid Size and Statistical Uncertainty on the Accuracy of VMAT Plans Based on Dosimetric Parameters for Head and Neck Cancers

Author:

Javid Asma1,Nagesh Jyothi2,Singh Rajpal3,Andavar S Senni4,C Shambhavi5,Sharan Krishna6,Kour Preeti7

Affiliation:

1. Department of Radiation Oncology, SMVDNSH, Katra, Jammu, India

2. Department of Radiation Therapy and Oncology, KMC, MAHE, Manipal, India

3. Department of Radiation Oncology, SMVDNSH, Kakryal, Katra, J&K

4. RSO, Department of Radiation Oncology, SMVDNSH, Kakryal, Katra, J&K

5. Department of Radiotherapy and Oncology, Manipal College of Health Professions (MCHP), MAHE, Manipal

6. Department of Radiotherapy and Oncology, KMC, MAHE, Manipal

7. Department of Psychiatry, ASCOMS, Jammu, India

Abstract

Aim Grid size and Statistical Uncertainty (SU) settings have an impact on the efficiency and accuracy of the treatment plans. Hence, it is very important, to find an optimum combination of the two-dose calculation parameters for efficient treatment planning. This study aims to study the impact of Grid Size and SU on Head and Neck cancer plans which were planned using the Volumetric-Modulated Arc Therapy (VMAT) technique. Materials and Methods 15 patients were selected for this retrospective study who had undergone radiation therapy at KMC, Manipal for various Head and Neck cancers. VMAT plans were generated for each case in Monaco 5.11 Treatment Planning System (TPS) using the Monte Carlo algorithm. For each patient, nine plans were generated in which the Grid size values were taken as 2 mm, 3 mm, and 5 mm and for each Grid size, SU settings were varied as 1%, 2%, and 5%. The plans were analysed and evaluated using outcome measures such as the Homogeneity Index (HI) and the Conformity Index (CI). Results The plans were evaluated as per the ICRU guidelines. In all the plans, PTV coverage achieved was above 95% with the maximum coverage (97.009) achieved with the 3 mm/1% combination. Overall, the effect of varying Grid Size and SU was insignificant in the plans generated, but there were few variations in the dose calculation parameters. For 2 mm/1%, 2 mm/2%, 2 mm/5%, 3 mm/1%, 3 mm/2%, 3 mm/5%, 5 mm/1%, 5 mm/2%, 5 mm/5%, the mean values of HI were 1.073, 1.078,1.078, 1.075, 1.0805, 1.0805, 1.068, 1.079, 1.089, and the mean values of CI were 0.968, 0.967, 0.967, 0.968, 0.958, 0.96, 0.954, 0.946, 0.948, respectively. Among all the combinations, the results for 5 mm/1% yielded more homogeneity, whereas 2 mm/1% and 3 mm/1% combinations resulted in better conformity. The 3 mm/1% combination gave maximum target coverage and quite fewer Monitor Units (MU) as well. Conclusion 3 mm Grid Size and 1% SU is suggested for the Head and Neck carcinomas planned using the VMAT technique.

Publisher

SAGE Publications

Subject

General Earth and Planetary Sciences,General Environmental Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3