Performance study of an isolated small scale Trombe wall with partially evacuated air gap

Author:

Ali Mahmud Hussain12ORCID,Mawlood Mahmood Khalid2,Jalal Rawand Ehsan2

Affiliation:

1. Mechanical and Mechatronics Engineering Department, College of Engineering, Salahaddin University, Erbil, Iraq

2. Mechanical Engineering Department, College of Engineering, University of Kirkuk, Kirkuk, Iraq

Abstract

The Trombe wall is a passive solar heating system that aims to mitigate heating load. However, its efficiency is impeded by significant heat loss through the glazing. To address this issue, a novel technique has been developed that involves partial evacuation of the space between the storage wall and the glazing. This approach, which has already found successful application in double-paned windows and solar collectors, is examined in this study to evaluate its impact on the performance of an isolated Trombe wall. An effectiveness criterion based on the ability of a system to preserve its stored thermal energy is defined and used for assessing the performance of a vacuumed system relative to a non-vacuumed one. An experimental test cell, composed of a solid concrete wall serving as a thermal storage and a glazing separated from the wall by an air gap, facing south is constructed in Kirkuk, Iraq. The wall is insulated at all its sides except the side facing the glass. The gap has been sealed meticulously to maintain a vacuum. Due to unrepeatability of the testing conditions experimentally, a numerical method and a computer code is also developed for simulation of the system. Measurement results obtained from the test cell under normal atmospheric pressure and a gage pressure of −0.3 bar of the air gap are used to validate the numerical method. The code is then used to simulate the performance of the system under the same ambient conditions but at different vacuum pressures of the air gap. Results obtained from the numerical tests show that partial evacuation of the air gap can be an efficient way to enhance the performance of the Trombe wall and the absolute pressure of 0.1 bar results in the most significant increase in the effectiveness of the studied model.

Publisher

SAGE Publications

Subject

Mechanical Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3