Analytical Evaluation and Comparison of Dupont aca® Lactate Dehydrogenase-1 (LD1) Isoenzyme Assay Diagnostic Efficiency for Acute Myocardial Infarction Detection with Other LD1 Methods and aca@ CK-MB

Author:

Painter Pennell C.1,Van Meter Stuart1,Dabbs Randal L.2,Clement Gerald E.3

Affiliation:

1. Department of Pathology, University of Tennessee Memorial Hospital

2. Emergency Department, University of Tennessee Memorial Hospital, Knoxville, TN

3. Department of Pathology, Lehigh Valley Hospital, Allentown, PA

Abstract

The purpose of this study was to examine the analtyical characteristics of a rapid new assay for lactate dehydrogenase 1 (LD1) isoenzyme on the Dupont aca® analyzer and the diagnostic efficiency of LD1 for detection of acute myocardial infarction (AMI) when used alone and with creatine kinase MB (CKMB). Total aca LD1 assay precision, with percent coefficients of variation (%CVs) of less than 3.2% from 56 U/L to 469 U/L LD1, across fifty assay days was excellent. Linearity was confirmed from 0 to 332 U/L and no detectable calibration drift was noted from 5 to 489 U/L over a ninety-day period. The aca LD1 results compared well with Roche Isomune-LD1, Abbott Spectrum A-Gent, Helena electrophoresis, and Beckman electrophoresis LD1 methods, giving r's from 0.987 to 0.994, slopes from 0.94 to 1.65, and y-intercepts from -2.95 to 6.94 U/L. Examination of 450 ambulatory subjects, about equally distributed by sex, yielded a 43 ±14 U/L aca LD1 patient reference interval. Serum samples from 159 consecutive patients at the University of Tennessee Memorial Hospital and 96 patients at Allentown Hospital, submitted for AMI detection assistance, were assayed in a single-blind study for LD1 and ion-exchange CKMB by Dupont aca methods, which provide automated results in ten minutes whenever needed. The aca LD1 assay yielded a clinical sensitivity of 89% and specificity of 95% for AMI with a decision threshold of 120 U/L. The diagnostic effi ciency of the aca LD1 assay was 94% at 120 U/L, which equaled or exceeded that of the three comparative LD1 methods. The predictive value of positive (PV+) and negative (PV-) results on the first sample collected were 80% and 85% for aca LD1, 65% and 90% for aca ion-exchange CKMB, and 83% and 90% when both tests were combined. Significantly, the PV+ and PV- results when two or more samples were assayed was improved to 88% and 95% for aca LD1, relatively constant at 65% and 97% for aca ion- exchange CKMB, and dramatically improved to 95% and 100% when both CKMB and LD1 tests were combined. The results from these two medical centers show that the aca LD1 assay provides useful clinical information for AMI diagnosis when employed alone or in combination with aca CKMB. These results also suggest that LD1 should be included in biochemical evaluations for AMI to attain optimal predictive values of results.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3