Affiliation:
1. Department of Cardiology, Deborah Heart and Lung Center, Affiliate of the University of Medicine and Dentistry of New Jersey, Browns Mills, NJ
Abstract
Twenty-seven patients had left ventricular ejection fraction (LVEF) mea sured by catheterization, single-plane angiography, and ultrafast computed to mography (cine CT). Twelve patients (mean age sixty-two years) had LVEF measured by use of the cine CT long-axis view LAV), and 15 patients (mean age fifty-eight years) had LVEF measured by use of the cine CT transaxial view (TAV). Cine CT LVEF was measured by means of two methods of edge detection (M1 and M2). A significant correlation was found between single-plane angiogra phy and cine CT LAV LVEF (M1, r=.96; M2, r=.93). A lesser correlation was found for catheterization vs TAV cine CT LVEF (M1, r=.77; M2, r=.81). There was no significant difference between the two methods of edge detection for determining LVEF (M1 vs M2: LAV, r=.98; TAV, r=.94); however, there was significant variability in cavity volumes. Therefore, the LAV is superior to the TAV for measurement of LVEF by cine CT; however, different methods of edge detection, though affecting volumes, may not affect LVEF.
Subject
Cardiology and Cardiovascular Medicine
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献