Complications related to intraaortic balloon counterpulsation pumping (IABP) remain a problem despite the development of small caliber balloon catheter shafts and introducer sheaths. The authors report their experience in counterpulsation-related complications of 201 consecutive patients who underwent 212 percutaneous counterpulsation balloon insertions from June 1989 to June 1996 by use of balloons with 8-9.5 French shafts. Of these, 82% were men and 36 (18%) were women, with a mean age of 61 ±12 years. Indications for counterpulsation were acute myocardial infarction (AMI) (67%), severe left ventricular failure without AMI (20%), dilated cardiomyopathy (4%), unstable angina (3%), high-risk supported percutaneous coronary angioplasty (2%), and others (4%). IABP was instituted at the bedside in the intensive care unit in 82 patients (39%) and in the catheterization laboratory in 130 (61%). Median duration of counterpulsation was 48 hours (range 30 minutes to 25 days) with successful weaning from counterpulsation in 70% (148 of 212) of procedures. Overall in-hospital mortality rate was 45% (90 of 201). The overall complication rate was 22/212 (10.4%). Major complications were present in 10/212 procedures (4.7%): 6 patients with limb ischemia (1 death directly attributed to this complication, 1 with associated septicemia and limb amputation, 3 requiring surgical thromboembolectomy, and 1 with persistent limb ischemia treated medically until his death caused by intractable left ventricular failure), 2 with important bleeding (1 fatal despite vascular surgical repair and 1 requiring blood transfusion) and 2 with balloon rupture requiring vascular surgery. Minor complications were present in 12 procedures (5.7%), 6 with limb ischemia, 3 with local bleeding, and 3 with catheter dysfunction. All of these resolved after balloon removal and required no further intervention. When limb ischemia did develop it occurred after a median delay of 24 hours following balloon insertion (range 2 to 98 hours). The only predictor of limb ischemia among baseline clinical and procedure-related variables was an age greater than 60 years. Compared with previous recent studies, the rate of complications observed in this study performed with small balloon catheters was acceptably low. Limb ischemia was the most frequent complication, often occurred early, and required further inter vention in half the cases.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3