Noninvasive Evaluation of Arterial Abnormalities in Young Patients with Neurofibromatosis Type 1

Author:

Ratti Gennaro,Di Salvo Giovanni,Martiniello Alfonso Roberto,Limongelli Giuseppe,Grieco Michela,Calabrese Elvira,Grassia Carolina,Iacono Aldo,Lama Giuliana,Tedesco Michele Adolfo1

Affiliation:

1. Medical Surgical Institute of Cardiology Second University of Naples Via Salita Due Porte, 14 80136, Naples, Italy

Abstract

Neurofibromatosis regroups at least two different autosomal dominant genetic disorders: neurofibromatosis type 1 (NF1) and neurofibromatosis type 2 (NF2). Vascular disease is an underestimated complication of NF1. Few studies are available on this, all based on case reports. Neurofibromin, NF1 protein product, has also been detected in aortic smooth muscle. The purpose of this study was to evaluate the physical properties of the vessels, by measuring the carotid-femoral pulse wave velocity (PWV). This parameter was assessed by the Complior®, a new noninvasive, validated device, used to screen a large population. The authors studied 64 neurofibromatosis patients (34 boys and 30 girls) with a mean age of 12 years (range 5-25 years). To investigate the presence of vascular lesions, aortic stiffness was evaluated by carotid-femoral PWV by using an automatic processor (Complior®). They compared data from the PWV with a control group (30 healthy children, 17 boys and 13 girls, mean age 11 years, range 5-23 years). The calculated mean PWV in the control group was 6.5 ±1.15 m/s. The mean PWV of the 64 young patients with NF1 was 6.3 ±1.02 m/s. There was no difference between the two groups (p=0.39). Nevertheless, analysis of the linear regression has shown a linear relationship between systolic blood pressure (SBP) and PWV in the control group, while in NF1 patients this relationship is not present. The authors suggest that the coexistence of different factors, such as intimal proliferation, thinning media, fragmentation of the elastic tissue, irregularity, stenosis and tortuosity of the vessels, dysplasia of the small vessels, that counterbalance PWV, normalize the mean value. They emphasize the impor tance of a careful vascular evaluation, using noninvasive method, such as Complior®. This device is well accepted by NF1 patients.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3