Angiography-Guided Routine Coronary Stent Implantation Results in Suboptimal Dilatation

Author:

Johansson Benny1,Olsson Hans1,Wennerblom Bertil1

Affiliation:

1. Örebro and Göteborg, Sweden

Abstract

The resistance of the atherosclerotic lesion counteracts the expansion of the stent, resulting in suboptimal stent expansion. Intravascular ultrasound provides more precise information on stent expansion than coronary angiography but adds cost and time to the percutaneous trans luminal coronary angiography procedure. The aim of this study was to evaluate the need for intravascular ultrasound at routine angiography-guided high pressure stent implantation by comparing stent expansion with predefined intracoronary ultrasound criteria for optimal stent implantation. In 32 patients, 48 stents (35 NIR, 12 AVE, and 1 Cordis) were implanted in A, B, and C stenoses using a high-pressure inflation technique until an optimal result was achieved according to angiography. Stent expansion was then evaluated by intravascular ultrasound as minimal lumen diameter, minimal lumen area, proximal and distal stent area, and a minimal lumen area symmetry index. These variables were then compared with the nominal stent size in vitro. Finally the stents were also evaluated with respect to the MUSIC criteria, ie, strict criteria regarding symmetry, apposition, and vessel geometry according to intravascular ultra sound after stent expansion. Forty-five stents could be completely analyzed. The mean balloon inflation pressure was 12.8 (range, 10-17) atm. The nominal stent size was not achieved in any patient. Minimal lumen diameter attained 77% and minimal lumen area 78% of expected nominal values (p< 0.0001), distal stent area 88% (p< 0.001), and proximal stent area 92% (ns). Application of the MUSIC criteria showed that almost all stents (96%) had good stent apposition and symmetry index. Optimal proximal stent entrance was found in 70%. Optimal minimal lumen area in comparison to the reference areas was present in 41%. This lead to fulfilling of all MUSIC criteria in 47% of the stents. If nominal stent size had been achieved, symmetry index and apposition would have been fulfilled in all cases and optimal minimal lumen area increased to 75%. Acceptable proximal entrance however would have decreased to 55% and the fulfillment of all MUSIC criteria would increase only to 52%. In routine angiography- guided stent implantation in stenoses with a wide range of severities using modern stents and high pressure inflation technique to reach a visually optimal result, the nominal stent size was never achieved mainly due to residual intrastent stenosis. If nominal stent size had been achieved, the results would have improved only marginally and would still be suboptimal in almost half of the stents. These results highlight the shortcoming of angiography and the need for intravascular ultrasound in choosing correct stent size.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3