Are Pressure-Volume Relations at End-Systole a Reflection of Left Ventricular Myocardial Contractility?

Author:

Ahmed S. Sultan1,Regan Timothy J.1

Affiliation:

1. Department of Medicine, College of Medicine and Dentistry of New Jersey—New Jersey Medical School, Newark, New Jersey

Abstract

The pressure-volume relation at end-systole is reportedly altered by changes in contractility. To explore the potential of this ratio in man 185 subjects including 23 normals (Group I) were studied. In 35 patients of Group II (16 with mitral stenosis, 7 with atrial septal defect, and 12 with cor pulmonale) ESP/ESV like an index of contractility measuring force-velocity-length rela tionship (Cy Ix) was insignificantly different from Group I (ESP/ESV and Cy Ix in I = 1.73 ± .31 mmHg/sec, 1.46 ± .09 cm/sec/cm vs 1.44 ± .10, 1.31 ± .05 in II respectively.) With significantly reduced Cy Ix (1.03 ± .04, P<0.00001) ESP/ ESV was likewise reduced (1.16 ± .07, P<0.007) in 108 patients with compen sated LV disease (34 with alcoholic cardiomyopathy, 16 coronary artery dis ease, 30 aortic valve disease, 8 hypertension and 16 with other heart muscle disease.) Like the Cy Ix (0.70 ± .05, P<0.001) ESP/ESV was even lower (0.84 ± .13, P<0.05) in 14 patients with decompensated LV (Group IV). It was insensitive to changes in pressure (angiotensin and volume (dextran). However unlike the Cy Ix it did not vary with acute changes in inotropy (exercise and pacing). The correlations between ESP/ESV and ejection fraction and contractility index in the entire series though weak, were significant (r = .50 and .20 respectively, each P<0.006). Exclusion of patients with aortic valve disease and hypertension in the analysis tended to improve the relationship between the contractility and end-systolic pressure-volume parameters. In the latter two subgroups neither the ESV nor the ESP/ESV ratio related to the contractil ity index, both parameters however did correlate significantly with the ejection fraction. These results indicate that end-systolic pressure-volume relations provide useful measures of LV performance in man, though not expressing the contractility either in all patients or under all situations.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

Reference32 articles.

1. Isometric Time-Tension Relationships as an Index of Myocardial Contractility

2. An index of the contractile state of the myocardium in man

3. V max as an Index of Contractile State in Man

4. Karliner JS, Peterson KL, Ross J. Jr: Myocardial mechanics: Assessment of isovolumic and ejection phase indices of left ventricular performance. In: Cardiac Catheterization and Angiocardiography, ed. by Grossman W, Philadelphia, Lea and Febiger, 1974 , pp. 188-206.

5. Problems in the use of indices of myocardial contractility

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Cardiovascular Physiology for Intensivists;Critical Heart Disease in Infants and Children;2019

2. Cardiovascular Physiology and Shock;Critical Heart Disease in Infants and Children;2006

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3