Sacral dysmorphism and its influence on hardware choice in sacral fractures: A scoping review

Author:

Alshaalan Fawaz N1ORCID,Al-Mohrej Omar A23,Hakeem Naif N2,Al-Asiri Jamal2,Johal Herman2

Affiliation:

1. Department of Orthopedic Surgery, King Faisal Specialist Hospital and Research Centre, Riyadh, Saudi Arabia

2. Division of Orthopaedic Surgery, Department of Surgery, McMaster University, Hamilton, Canada

3. Section of Orthopedic Surgery, Department of Surgery, King Abdullah Bin Abdulaziz University Hospital, Princess Nourah Bint Abdul Rahman University, Riyadh, Saudi Arabia

Abstract

Purpose In the setting of sacral fractures, percutaneous screw fixation is a reliable, safe, and minimally invasive method for managing most stable and unstable fractures. However, significant variations in sacral anatomy due to sacral dysmorphism (SDM) could prevent safe implementation. This scoping review aimed to highlight such a detrimental yet under-reported variable in managing sacral fractures. Methods A scoping review was conducted following the Arksey and O’Malley framework for scoping studies. A comprehensive literature search of four electronic databases was conducted to identify relevant peer-reviewed studies. Data were extracted from eligible articles to summarize, collate, and create a narrative account of the findings. Results Twenty-one articles were included in our review (18 level III, two level II, and one level I). Studies were categorized into three main groups based on the investigated outcomes: prevalence and determinants of SDM, effect of SDM on the surgical corridor, and efficacy of different intra-operative imaging modalities. The prevalence of SDM ranged from 10 to 85%. The presence of SDM decreased the available surgical corridor at S1, with a compensated increase at S2 and S3. Mixed results regarding accuracy and revision rate were identified between different intra-operative imaging techniques. Conclusion SDM represents consistent yet atypical “safe zone,” sizes, and angles that require careful analysis and technique alterations when placing upper and second sacral segment screws. Considering their limited availability, high cost, and mixed results, navigated imaging systems represent a promising technique that requires more rigorous examination of its efficacy before widespread adoption.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3