Successful sterilization and immediate reimplantation of extruded femoral diaphyseal segment: A case report and review of literature

Author:

Sodhai Vivek1ORCID,Pradhan Chetan1,Sancheti Parag2,Shyam Ashok34

Affiliation:

1. Department of Trauma, Sancheti Institute for Orthopaedics and Rehabilitation, Pune, Maharashtra, India

2. Department of Orthopaedics, Sancheti Institute for Orthopaedics and Rehabilitation, Pune, Maharashtra, India

3. Department of Research, Sancheti Institute for Orthopaedics and Rehabilitation, Pune, Maharashtra, India

4. Department of Research, Indian Orthopaedic Research Group, Thane, Maharashtra, India

Abstract

Extrusion of bone is a rare situation in open fractures due to high energy trauma. There are few studies, reporting successful reimplantation of the extruded bone segment using various sterilization and fixation protocols. However, there are no definitive treatment strategies for this challenging situation. We report a case of 30-year-old male patient with grade IIIB compound right distal femur fracture with an extruded long bone segment, who was treated with successful sterilization and immediate reimplantation of an extruded long diaphyseal segment of distal femur following extensive cleaning with sterile normal saline, removal of debris with scrubbing by sterile brush, soakage in the broad-spectrum antimicrobial solution for 30 min, sterilization by autoclaving at 121°C for 45 min, and reimplantation during stable internal fixation with lateral distal femur locking plate using Arbeitsgemeinschaft für Osteosynthesefragen techniques. At 3 months, iliac crest bone grafting, osteoperiosteal flaps, and augmented fixation with a medial locking plate were performed through a subvastus approach for a void in the medial supracondylar femur region. Intraoperatively, punctate bleeding was observed from the reimplanted fragment. Infection was ruled out with normal leukocyte count, C-reactive protein marker, no evidence of unhealthy granulation tissue, and a sterile culture report from the fracture site. The fracture healed in 12 months and the patient had good functional outcome with a lower extremity functional score of 80% and knee range of motion of 110° at short-term follow up of 2 years without any complication. Decision of reimplantation is individualized depending on the time of presentation, contamination, and comminution of extruded fragment with scarce literature on standard treatment strategies. In our case, early presentation, meticulous debridement, unique sterilization technique, immediate reimplantation, and augmented dual distal femur plating with bone grafting aided in achieving successful union with good functional outcome and knee range of motion, avoiding any complications.

Publisher

SAGE Publications

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3