Accuracy of maximal acceleration time of pedal arteries to diagnose critical limb-threatening ischemia

Author:

Trihan Jean-Eudes12ORCID,Croquette Magali3,Hersant Jeanne24ORCID,Prigent Romain1,Fontaine Cedric1,Henni Samir24,Lanéelle Damien56ORCID

Affiliation:

1. Vascular Medicine Unit, Hospital of Cholet, Cholet, Pays de la Loire, France

2. Vascular Medicine Department, University Hospital Angers, Angers, Pays de la Loire, France

3. Vascular Medicine Unit, University Hospital Centre Poitiers, Poitiers, Nouvelle-Aquitaine, France

4. UMR CNRS 1083, INSERM 6015, LUNAM University, Angers, France

5. Vascular Medicine Unit, University Hospital Côte de Nacre, Caen, Normandie, France

6. UNICAEN, INSERM 1075, COMETE, Caen, Normandie, France

Abstract

Introduction: Maximal acceleration time of distal arteries of the foot (ATmax) is correlated to ankle–brachial index (ABI) and toe–brachial index (TBI), and seems very promising in diagnosing severe peripheral artery disease (PAD) and especially critical limb-threatening ischemia (CLTI). Our goal was to confirm the cut-off value of 215 ms to predict a toe pressure (TP) ⩽ 30 mmHg. Methods: A 4-month retrospective study was conducted on patients addressed for suspicion of PAD. Demographic data, ABI, TBI, and Doppler ultrasound scanning parameters of the dorsal pedis and lateral plantar arteries (DPA and LPA) were recorded. Results: A total of 137 patients with 258 lower limbs were included. ATmax was highly correlated to TBI ( r = −0.89, p < 0.001). With the cut-off value of 215 ms, ATmax was effective to diagnose TP ⩽ 30 mmHg with a sensitivity of 93% [95% CI 77–99], a specificity of 96% [95% CI 92–98], a positive predictive value of 73% [95% CI 56–86], a negative predictive value of 99% [95% CI 97–100], and an area under the receiver operating characteristics curve of 0.99 [95% CI 0.98–1.00]. ATmax also showed promising results to rule out PAD in healthy patients. Conclusion: ATmax is a reliable diagnostic tool to diagnose low TP and could be a new easily performed hemodynamic criterion for diagnosis of CLTI.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3