Preprocedural imaging modalities in patients undergoing iliocaval venous recanalization and stent placement

Author:

Müller Markus1ORCID,Wolf Florian2,Loewe Christian2,Beitzke Dietrich2,Zehetmayer Sonja3,Gschwandtner Michael E1,Willfort-Ehringer Andrea1,Koppensteiner Renate1,Schlager Oliver1

Affiliation:

1. Department of Medicine II, Division of Angiology, Medical University of Vienna, Vienna, Austria

2. Department of Bioimaging and Image-Guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Vienna, Austria

3. Center for Medical Statistics, Informatics and Intelligent Systems, Medical University of Vienna, Vienna, Austria

Abstract

Purpose: To determine the diagnostic accuracy of preinterventional imaging modalities in patients being evaluated for iliocaval venous recanalization and stent placement. Methods: Consecutive patients with iliocaval postthrombotic obstructions or nonthrombotic iliac vein lesions (NIVL), who were scheduled for recanalization, underwent duplex ultrasound (DUS), magnetic resonance venography (MRV), multiplanar venography (MPV), and intravascular ultrasound (IVUS). The diagnostic accuracies of DUS, MRV, and MPV were analyzed using IVUS as reference. Results: A total of 216 limbs in 108 patients (80 patients with postthrombotic obstructions, 28 patients with NIVL) were examined. In patients with postthrombotic obstructions, the diagnostic sensitivities for the detection of lesions of the common femoral vein were 81% (95% CI 71–89%) for DUS, 76% (95% CI 65–85%) for MRV, and 86% (95% CI 76–93%) for MPV. The sensitivities for detecting lesions of the iliac veins were 96% (95% CI 89–99%) for DUS, 99% (95% CI 92–100%) for MRV, and 100% (95% CI 94–100%) for MPV. Regarding the inferior vena cava, the sensitivities were 44% (95% CI 24–65%) for DUS, 52% (95% CI 31–73%) for MRV, and 70% (95% CI 47–86%) for MPV. The sensitivities for detecting NIVL were 58% (95% CI 34–79%) for DUS, 90% (95% CI 68–97%) for MRV, and 95% (95% CI 73–99%) for MPV. Conclusion: In patients scheduled for recanalization of iliocaval postthrombotic obstructions, the sensitivities of DUS, MRV, and MPV were similar. In patients with suspected inferior vena cava involvement and in patients with NIVL, additional imaging with MR or conventional venography is required.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3