Tranexamic Acid in Hip Hemiarthroplasty Surgery: A Retrospective Analysis of Perioperative Outcome

Author:

Wilharm Arne1ORCID,Wutschke Isabell1,Schenk Philipp2,Hofmann Gunther Olaf1

Affiliation:

1. Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Jena, Jena, Germany

2. Department of Research Executive, BG Klinikum Bergmannstrost Halle, Halle, Germany

Abstract

Introduction: Implantation of a dual-head hip prosthesis to treat medial femoral neck fractures is often associated with significant blood loss. In elective endoprosthetics procedures, it has already been demonstrated that administration of tranexamic acid (TXA) reduces blood loss and need for postoperative transfusions, as well as reducing the frequency of postoperative complications. The aim of this study is to show whether the administration of TXA also leads to a reduction in perioperative blood loss and haemorrhage-associated complications when applied as part of treatment of femoral neck fractures using a dual-head prosthesis. Methods: In a single-centre retrospective cohort study, 1 g TXA i.v. was administered preoperatively to 93 patients who had suffered from femoral neck fractures. This group was compared to a comparison group of 65 patients who did not receive TXA (nonTXA). Outcomes were evaluated on the basis of perioperative blood loss, frequency of transfusion, and frequency of specific complications occurring. Results: The transfusion rate in the TXA group was 6% lower, whereby the volume of blood transfused was 26.7% lower than in the nonTXA group. However, neither result was significant. The calculated perioperative blood loss remained the same. Similarly, the incidence of postoperative renal failure was not significantly lower in the TXA group, at 6.5%, as compared to the nonTXA group (7.7%). A higher rate of complications or deaths as a result of TXA administration was not observed. The tranexamic acid effect seems to be related to the dose. Conclusion: Preoperative administration of TXA during implantation of a dual-head prosthesis for treatment of a femoral neck fracture does not lead to an increased complication rate. The study revealed a trend towards fewer transfusions required, but a significant reduction in blood loss could not be demonstrated. There should be further investigation of other factors influencing blood loss, in particular the dosing regimen followed for perioperative administration of TXA. Level of Evidence: Level 4: retrospective case-control study

Publisher

SAGE Publications

Subject

Geriatrics and Gerontology,Rehabilitation,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3